X-ray Emission as a Diagnostic for from Pseudospark-Sourced Electron Beams

نویسندگان

  • D. Bowes
  • H. Yin
  • D. Chen
چکیده

X-ray emission has been achieved using an electron beam generated by a pseudospark low-pressure discharge and utilised as a diagnostic for beam detection. A 300 A, 34 kV PS-sourced electron beam pulse of 3 mm diameter impacting on a 0.1 mm-thick molybdenum target generated X-rays which were detected via the use of a small, portable X-ray detector. Clear X-ray images of a micro-sized object were captured using an X-ray photodetector. This demonstrates the inducement of proton induced X-ray emission (PIXE) not only as an indicator of beam presence but also as a future X-ray source for smallspot X-ray imaging of materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigations of High Voltage Pulsed Pseudospark Discharge and Intense Electron Beams

A high voltage pulsed discharge device which can produce intense high energy electron beam named “pseudospark” is presented in this work. This discharge device is able to hold 10s of kV voltage, kA current and 10 10 -10 11 A/s current rising rate. The pseudospark device is also a simply-constructed source for intense electron beam with high energy. The presented experimental investigation is fo...

متن کامل

A proton induced X-ray emission (PIXE) analysis of concentration of trace elements in varicose veins

Background: Proton induced X-ray emission (PIXE) has been applied as reliable and improved techniques in this study to compare concentration of various trace elements in normal and abnormal varicose veins. Materials and Methods: Five samples from normal veins and 13 samples from varicose veins bombarded by 2.0 MeV energy proton beams produced by a Van de Graff accelerator in vacuum. T...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Synthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors

Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015