BACKGROUND In a previous in vitro study, we confirmed that small-caliber nanofibrous polyurethane (PU) vascular grafts have favorable mechanical properties and biocompatibility. In the present study, we examined the in vivo biocompatibility and stability of these grafts. METHODS Forty-eight adult male beagle dogs were randomly divided into two groups receiving, respectively, polyurethane (PU) or polytetrafluoroethylene (PTFE) grafts (n = 24 animals / group). Each group was studied at 4, 8, 12, and 24 weeks after graft implantation. Blood flow was analyzed by color Doppler ultrasound and computed tomography angiography. Patency rates were judged by animal survival rates. Coverage with endothelial and smooth muscle cells was characterized by hematoxylin-eosin and immunohistological staining, and scanning electron microscopy (SEM). RESULTS Patency rates were significantly higher in the PU group (p = 0.02 vs. PTFE group). During the first 8 weeks, endothelial cells gradually formed a continuous layer on the internal surface of PU grafts, whereas coverage of PTFE graft by endothelial cells was inhomogeneous. After 12 weeks, neointimal thickness remained constant in the PU group, while PTFE group showed neointimal hyperplasia. At 24 weeks, some anastomotic sites of PTFE grafts became stenotic (p = 0.013 vs. PU group). Immunohistological staining revealed a continuous coverage by endothelial cells and an orderly arrangement of smooth muscle cells on PU grafts. Further, SEM showed smooth internal surfaces in PU grafts without thrombus or obvious neointimal hyperplasia. CONCLUSIONS Small-caliber nanofibrous PU vascular grafts facilitate the endothelialization process, prevent excessive neointimal hyperplasia, and improve patency rates.
منابع مشابه
مقایسه میزان کارایی و عوارض گرافتهای عروقی پلییورتان و پلیتترافلورواتیلن در بیماران نیازمند همودیالیز مزمن
Abstract Background: Twenty percent of dialysis patients eventually require arterial grafts as the only method of vascular access for hemodialysis. Polyurethane and ploy tetra fluoro ethylene grafts have been used for years for vascular access in hemodialysis patients. The purpose of this study was to compare the efficacy and complications of these two types of grafts. Methods: In this rand...
متن کاملAntithrombogenic property of bone marrow mesenchymal stem cells in nanofibrous vascular grafts.
Nanostructured biomaterials have tremendous potential for tissue engineering. However, the performance and integration of the nanomaterials in vivo are not well understood. A challenge in vascular tissue engineering is to develop optimal scaffolds and establish expandable cell sources for the construction of tissue-engineered vascular grafts that are nonthrombogenic and have long-term patency. ...
متن کاملPaclitaxel-eluting biodegradable synthetic vascular prostheses: a step towards reduction of neointima formation?
BACKGROUND Clinical small-caliber vascular prostheses are unsatisfactory. Reasons for failure are early thrombosis and late intimal hyperplasia. We thus prepared biodegradable small-caliber vascular prostheses using electrospun polycaprolactone (PCL) with slow-releasing paclitaxel (PTX), an antiproliferative drug. METHODS AND RESULTS PCL solutions containing PTX were used to prepare nonwoven ...
متن کاملFabrication and characterization of nanofibrous tricuspid valve scaffold based on polyurethane for heart valve tissue engineering
Objective(s): Tissue engineering represents a new approach to solve the current complications of the heart valve replacements by offering viable valve prosthesis with growth and remodeling capability. In this project, electrospinning and dip coating techniques were used to fabricate heart valve constructs from medical grade polyurethane (PU). Methods: Fir...
متن کاملVascular Tissue Engineering: Effects of Integrating Collagen into a PCL Based Nanofiber Material
The engineering of vascular grafts is a growing field in regenerative medicine. Although numerous attempts have been made, the current vascular grafts made of polyurethane (PU), Dacron®, or Teflon® still display unsatisfying results. Electrospinning of biopolymers and native proteins has been in the focus of research to imitate the extracellular matrix (ECM) of vessels to produce a small calibe...