A Latent Markov Modelling Approach to the Evaluation of Circulating Cathodic Antigen Strips for Schistosomiasis Diagnosis Pre- and Post-Praziquantel Treatment in Uganda
نویسندگان
چکیده
Regular treatment with praziquantel (PZQ) is the strategy for human schistosomiasis control aiming to prevent morbidity in later life. With the recent resolution on schistosomiasis elimination by the 65th World Health Assembly, appropriate diagnostic tools to inform interventions are keys to their success. We present a discrete Markov chains modelling framework that deals with the longitudinal study design and the measurement error in the diagnostic methods under study. A longitudinal detailed dataset from Uganda, in which one or two doses of PZQ treatment were provided, was analyzed through Latent Markov Models (LMMs). The aim was to evaluate the diagnostic accuracy of Circulating Cathodic Antigen (CCA) and of double Kato-Katz (KK) faecal slides over three consecutive days for Schistosoma mansoni infection simultaneously by age group at baseline and at two follow-up times post treatment. Diagnostic test sensitivities and specificities and the true underlying infection prevalence over time as well as the probabilities of transitions between infected and uninfected states are provided. The estimated transition probability matrices provide parsimonious yet important insights into the re-infection and cure rates in the two age groups. We show that the CCA diagnostic performance remained constant after PZQ treatment and that this test was overall more sensitive but less specific than single-day double KK for the diagnosis of S. mansoni infection. The probability of clearing infection from baseline to 9 weeks was higher among those who received two PZQ doses compared to one PZQ dose for both age groups, with much higher re-infection rates among children compared to adolescents and adults. We recommend LMMs as a useful methodology for monitoring and evaluation and treatment decision research as well as CCA for mapping surveys of S. mansoni infection, although additional diagnostic tools should be incorporated in schistosomiasis elimination programs.
منابع مشابه
Use of circulating cathodic antigen strips for the diagnosis of urinary schistosomiasis.
Rapid diagnostic tests are needed for the implementation and monitoring of national schistosomiasis control programmes. The field applicability of the circulating cathodic antigen (CCA) urine reagent strip for the diagnosis of Schistosoma haematobium infection was evaluated among 265 pre- and primary schoolchildren aged 2-19 years in a rural area of Zimbabwe. The CCA strip was compared with egg...
متن کاملSensitivity and Specificity of Multiple Kato-Katz Thick Smears and a Circulating Cathodic Antigen Test for Schistosoma mansoni Diagnosis Pre- and Post-repeated-Praziquantel Treatment
BACKGROUND Two Kato-Katz thick smears (Kato-Katzs) from a single stool are currently recommended for diagnosing Schistosoma mansoni infections to map areas for intervention. This 'gold standard' has low sensitivity at low infection intensities. The urine point-of-care circulating cathodic antigen test (POC-CCA) is potentially more sensitive but how accurately they detect S. mansoni after repeat...
متن کاملDiagnosis of schistosomiasis by reagent strip test for detection of circulating cathodic antigen.
A newly developed reagent strip assay for the diagnosis of schistosomiasis based on parasite antigen detection in urine of infected individuals was evaluated. The test uses the principle of lateral flow through a nitrocellulose strip of the sample mixed with a colloidal carbon conjugate of a monoclonal antibody specific for Schistosoma circulating cathodic antigen (CCA). The strip assay to diag...
متن کاملNew Approaches with Different Types of Circulating Cathodic Antigen for the Diagnosis of Patients with Low Schistosoma mansoni Load
BACKGROUND Schistosomiasis mansoni is a debilitating and sometimes fatal disease. Accurate diagnosis plays a key role in patient management and infection control. However, currently available parasitological methods are laborious and lack sensitivity. The selection of target antigen candidates has turned out to be a promising tool for the development of more sensitive diagnostic methods. In our...
متن کاملRapid clearance of Schistosoma mansoni circulating cathodic antigen after treatment shown by urine strip tests in a Ugandan fishing community – Relevance for monitoring treatment efficacy and re-infection
Schistosomiasis control and elimination has priority in public health agendas in several sub-Saharan countries. However, achieving these goals remains a substantial challenge. In order to assess progress of interventions and treatment efficacy it is pertinent to have accurate, feasible and affordable diagnostic tools. Detection of Schistosoma mansoni infection by circulating cathodic antigen (C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2013