Three-dimensional conformal external beam radiotherapy versus the combination of external radiotherapy with high-dose rate brachytherapy in localized carcinoma of the prostate: comparison of acute toxicity.

نویسندگان

  • Renata Soumarová
  • Lubos Homola
  • Hana Perková
  • Miroslav Stursa
چکیده

AIMS AND BACKGROUND Radiotherapy represents one of the basic therapeutic methods in treatment of localized carcinoma of the prostate. Optimal irradiation dose is the cornerstone of a successful treatment. Along with local control of the disease and overall survival of the patient, possible acute and long-term side effects need to be monitored very closely. METHODS A non-randomized prospective study comparing the acute genitourinary and gastrointestinal toxicity in patients irradiated for localized carcinoma of the prostate. Fifty-seven patients were treated with three-dimensional conformal external beam radiotherapy alone, and in the second treatment arm a combination of external beam radiotherapy and high-dose rate brachytherapy was employed in 40 patients. RESULTS Three-dimensional conformal external beam radiotherapy. Acute G1 genitourinary toxicity was recorded in 35.1% of patients, G2 in 22.8%, and G2-3 in one patient (1.7%). Acute gastrointestinal toxicity was experienced by 54.4% of patients, G1 in 28.1%, G2 in 17.5%, and G3 in 8.8%. Three-dimensional conformal external beam radiotherapy + brachytherapy. Acute G1 genitourinary toxicity was recorded in 37.5% and grade 2 in 15% of the patients. Only G1 acute gastrointestinal toxicity was recorded in 40% of the patients. CONCLUSIONS Acute G1 genitourinary toxicity was experienced by a similar percentage of patients in both treatment arms. Acute G2 genitourinary toxicity was more frequent in the three-dimensional conformal radiotherapy arm. Higher acute genitourinary toxicity, G3 or G4, was recorded only in one patient per treatment arm. Acute gastrointestinal toxicity was more frequent in the three-dimensional conformal radiotherapy arm. Higher acute gastrointestinal toxicity, G2 and G3, was only observed in the three-dimensional conformal radiotherapy arm. The acute toxicity observed was of a low grade. The combination of external beam radiotherapy with brachytherapy resulted in a lower incidence of gastrointestinal toxicity than external beam radiotherapy alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

درمان داخل حفره‌ای در مبتلایان سرطان سرویکس: پرتودهی با دوز متوسط در یک مطالعه آینده‌نگر

Background: Treatment of cervical carcinoma is routinely performed with Low Dose Rate (LDR) brachytherapy, but Brachytherapy in our department is done with Medium Dose Rate (MDR) due to the technical characteristics of the machine available here. Thus we decided to evaluate the results of this treatment in our department in a prospective study. Methods: Between March 2006 and July 2008, 140 pa...

متن کامل

Acute Toxicity of Three Dimensional Conformal Concurrent Chemoradiation with Dose Optimization for External Beam Radiation in Carcinoma Cervix—A Prospective Study

Aim: To prospectively evaluate the acute toxicity of 3D conformal radiotherapy with dose optimization in patients with carcinoma cervix. Materials and Methods: Carcinoma cervix patients stage IIB to IIIB (n = 30) treated during November 2011 to May 2013 at the institution with 3D conformal chemo-radiation were included in the study. They received weekly Cisplatin 40 mg/m2 for a maximum of 5 cyc...

متن کامل

Efficacy and Safety of High-Dose-Rate Brachytherapy of Single Implant with Two Fractions Combined with External Beam Radiotherapy for Hormone-Naïve Localized Prostate Cancer

The purpose of this study was to evaluate the efficacy and safety of high-dose-rate (HDR) brachytherapy of a single implant with two fractions plus external beam radiotherapy (EBRT) for hormone-naïve prostate cancer in comparison with radical prostatectomy. Of 150 patients with localized prostate cancer (T1c-T2c), 59 underwent HDR brachytherapy plus EBRT, and 91 received radical prostatectomy. ...

متن کامل

Dosimetric comparison between intensity modulated radiotherapy and three dimensional conformal radiotherapy planning in patients with locally advanced cervical carcinoma

Background: External beam radiotherapy (EBRT) is mainstay of treatment in patients with locally advanced cervical carcinoma (LACC). Three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are mainly used in EBRT. However which one is superior is still controversial. Materials and Methods: Forty patients of LACC treated with IMRT were selected for this study....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Tumori

دوره 93 1  شماره 

صفحات  -

تاریخ انتشار 2007