Matrix² coils in embolization of intracranial aneurysms: 1-year outcome and comparison with bare platinum coil group in a single institution.

نویسندگان

  • S W Youn
  • S-H Cha
  • H-S Kang
  • Y D Cho
  • M H Han
چکیده

BACKGROUND AND PURPOSE The endosaccular occlusion by using BPC has been useful in the treatment of intracranial aneurysms, but its limited durability remains a deep-seated drawback. The Matrix² coil, one of the bioactive-coated coils, had been developed to improve this limited durability. To evaluate durability of Matrix² coils after embolization of intracranial aneurysms, we retrospectively compared 1-year outcomes with that of BPC groups. MATERIALS AND METHODS A group of 121 aneurysms in 114 patients were embolized by using Matrix² coils between April 2006 and September 2008. The BPC group consisted of 151 aneurysms in 137 patients embolized by using BPCs alone between October 2007 and October 2008. The initial outcomes including packing densities, occlusion grades, and periprocedural complications, and the 1-year outcomes on MR angiography were retrospectively compared between the 2 groups. RESULTS The Matrix² coil group and BPC group with similar baseline demographic characteristics revealed comparable initial outcomes. The rates of overall recurrence, major recanalization, and retreatment were 17.4%, 14.0%, and 10.7% versus 7.3%, 5.3%, and 4.6%, respectively (P = .066). However, the rates of subgroups with aneurysm volumes between 50 and 200 mm³ were 23.7%, 13.1%, and 10.5% versus 2.2%, 0%, and 0% (P = .022), respectively. The rates of subgroups with packing attenuation <30% were 38.3%, 31.9%, and 23.4% versus 13.3%, 11.7%, and 10% (P = .025), respectively. There were no differences in packing attenuation (P = .152), initial occlusion grade (P = .098), and 1-year outcomes (P = .209) according to the length of Matrix² coils used. CONCLUSIONS Overall, initial and 1-year outcomes of the Matrix² coil group were comparable to those of the BPC group. However, in certain subgroups of aneurysm volume and packing attenuation, the 1-year durability of Matrix² coils was inferior to that of the BPC group.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short-term outcome of intracranial aneurysms treated with polyglycolic acid/lactide copolymer-coated coils compared to historical controls treated with bare platinum coils: a single-center experience.

BACKGROUND AND PURPOSE Aneurysm recanalization is an innate problem in endovascular treatment of aneurysms with coils. A coated coil system, covered with a bioabsorbable polymeric material (polyglycolic acid/lactide copolymer, PGLA), was developed to accelerate intra-aneurysmal clot organization and fibrosis. The purpose of this study was to evaluate the efficacy and safety of the PGLA-coated c...

متن کامل

Endosaccular treatment of intracranial aneurysms using matrix coils: early experience and midterm follow-up.

BACKGROUND AND PURPOSE The authors report their experience using Matrix coils in the treatment of cerebral aneurysms. METHODS The outcomes of 72 consecutive patients (76 aneurysms) who underwent coiling using Matrix coils at our institution were retrospectively analyzed. RESULTS Seventy-four aneurysms in 70 patients were coiled using Matrix coils (ranging 3% to 100% by coil length; mean 68....

متن کامل

Matrix detachable coils for the endovascular treatment of intracranial aneurysms: analysis of early angiographic and clinical outcomes.

BACKGROUND AND PURPOSE Endovascular coil embolization has become an accepted alternative for the treatment of intracranial aneurysms. The purpose of this study was to evaluate the clinical safety and the angiographic stability of aneurysm occlusion with a new class of biologically active platinum coils after a 6-month period. METHODS Twenty-five patients with 25 intracranial aneurysms were tr...

متن کامل

Second-Generation Hydrogel Coils for the Endovascular Treatment of Intracranial Aneurysms

BACKGROUND AND PURPOSE Endovascular embolization of intracranial aneurysms with hydrogel-coated coils lowers the risk of major recurrence, but technical limitations (coil stiffness and time restriction for placement) have prevented their wider clinical use. We aimed to assess the efficacy of softer, second-generation hydrogel coils. METHODS A randomized controlled trial was conducted at 22 ce...

متن کامل

Single-institution experience with matrix coils in the treatment of intracranial aneurysms: comparison with same-center outcomes with the use of platinum coils.

BACKGROUND AND PURPOSE This study was undertaken to analyze the outcomes and treatment-related complications of the polyglycolic/polylactic acid (PGLA)-coated Matrix platinum coils in the treatment of intracranial aneurysms and compare these results with those derived from the same single-institutional experience with use of uncoated, bare platinum coils. MATERIALS AND METHODS In this study, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 32 9  شماره 

صفحات  -

تاریخ انتشار 2011