A laboratory and clinical investigation comparing 2 oscillating/rotating electric toothbrushes.

نویسندگان

  • M M Danser
  • G M Driesen
  • M F Timmerman
  • van der Velden
  • G A van der Weijden
چکیده

BACKGROUND/AIMS The purpose of the study was to investigate the efficacy of plaque removal by 2 different toothbrushes in a laboratory model and in a clinical study. METHOD The 2 brushes used were the Philips/Jordan HP 735 and the Braun Oral-B Ultra Plaque Remover (D9). Both were compared in a laboratory study (using a robot system) and a short-term clinical study. For the laboratory study, plaque substitute was applied to the artificial teeth of ten typodonts, which were cleaned by a robot for 2 min. The remaining plaque substitute was measured on buccal and lingual/palatal surfaces, as well as gumline and interproximal sites, using a computerized vision system. The clinical study included 23 non-dental students. All subjects received a single oral prophylaxis and were asked not to brush their teeth for 48 h prior to their appointment. After the amount of plaque had been evaluated at 6 sites per tooth, subjects brushed in a random split-mouth order with the 2 electric toothbrushes, after which the amount of plaque was re-evaluated. RESULTS The results of the laboratory study showed that, for all surfaces combined, the mean removal of plaque substitute for both brushes was the same. However, at the vestibular and the approximal vestibular surfaces, the reduction in plaque substitute was significantly higher (p<0.01) with the Braun toothbrush compared to the Philips. In the clinical study, the mean overall plaque reduction for the Braun toothbrush (74%) was significantly higher than for the Philips (66%). Further analysis revealed that the significant difference in favour of the Braun brush was mainly due to plaque removal from the approximal vestibular and the approximal lingual sites. CONCLUSIONS In conclusion, both the laboratory and clinical study show that the Braun Oral-B Ultra Plaque Remover (D9) is more effective than the Philips/Jordan HP 735. Both study models indicate that this difference is greatest on the approximal vestibular surfaces.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manual orthodontic vs. oscillating-rotating electric toothbrush in orthodontic patients: a randomised clinical trial.

AIM To compare the efficacy of manual and oscillating-rotating electric toothbrushes in removing plaque and reducing gingivitis in patients with fixed orthodontic appliances. STUDY DESIGN Randomised clinical trial. MATERIALS AND METHODS 20 subjects aged 10 to 14 years (8 males; 12 females) scheduled for fixed orthodontic treatment were enrolled, randomly divided into two groups, A and B, an...

متن کامل

A comparative clinical study of extrinsic tooth stain removal with two electric toothbrushes [Braun D7 and D9] and a manual brush.

PURPOSE To evaluate the efficacy and safety of two oscillating/rotating toothbrushes, (Braun Oral-B Plaque Remover-D7 and Braun Oral-B Ultra Plaque Remover-D9) and a manual toothbrush with respect to removing extrinsic dental stain. MATERIALS AND METHODS This randomized, three-way cross-over study investigated 24 subjects entering the trial, which was divided into three, 5-day periods. Over t...

متن کامل

A robot comparison of efficacy of battery toothbrushes

This laboratory study to compare the cleaning efficacy of battery-operated power toothbrushes was carried out in two phases. Firstly, the Braun Oral-B D4/EB4 was compared with the Colgate Actibrush and secondly the D4/EB4 was compared with the Dr. Best Powerclean. All three brushes are battery-operated and have a small round brushhead with an oscillating/rotating action. They differ, however, w...

متن کامل

In vitro tooth cleaning efficacy of electric toothbrushes around brackets.

This in vitro study assessed the cleaning efficacy of different electric toothbrushes around upper incisor brackets. Standard and Mini Diamond brackets were fixed on black-stained teeth. The teeth were coated with white titanium oxide and brushed in a machine twice for 1 minute each. Twelve different brush heads with either a wiping or an oscillating-rotating action were tested. After brushing,...

متن کامل

A novel oscillating-rotating power toothbrush with SmartGuide: designed for enhanced performance and compliance.

AIM The aim of this article is to provide a review of common power toothbrush technologies with a focus on the oscillating-rotating motion used in a novel toothbrush; describe features to drive compliance such as the "SmartGuide" innovation; and finally recommend steps to motivate patients to adopt a power toothbrush as part of their home care regimen. BACKGROUND Contemporary power toothbrush...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical periodontology

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2000