Mandibular advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success.

نویسندگان

  • Marie Marklund
  • Hans Stenlund
  • Karl A Franklin
چکیده

STUDY OBJECTIVE To evaluate the tolerability and to find predictors of treatment success for an individually adjusted, one-piece mandibular advancement device in patients with snoring and obstructive sleep apnea. DESIGN Prospective study. SETTING Departments of Respiratory Medicine and Orthodontics, Umeå University. PATIENTS Six hundred nineteen of 630 patients (98%), who consecutively received treatment for sleep apnea and snoring from February 1989 to August 2000, were followed up. They had a mean apnea-hypopnea index of 16 (range, 0.0 to 76) and a mean body mass index of 28 (range, 19 to 42). MEASUREMENTS Interviews, questionnaires, and overnight sleep apnea recordings. Patients with an apnea-hypopnea index of >or=10 in the supine and/or lateral position were considered to have obstructive sleep apnea. A lateral apnea-hypopnea index of < 10, together with a supine apnea-hypopnea index of >or= 10, defined supine-dependent sleep apneas. RESULTS One hundred forty-eight of the 619 patients (24%) discontinued treatment. Female gender predicted treatment success, defined as an apnea-hypopnea index of < 10 in both the supine and lateral positions, with an odds ratio of 2.4 (p = 0.01). In the women, the odds ratios for treatment success were 12 for mild sleep apnea (p = 0.04), and 0.1 for complaints of nasal obstruction (p = 0.03). In the men, the odds ratios for treatment success were 6.0 for supine-dependent sleep apneas (p < 0.001), 2.5 for mild sleep apnea (p = 0.04), 1.3 for each millimeter of mandibular advancement (p = 0.03), and 0.8 for each kilogram of weight increase (p = 0.001). CONCLUSIONS The mandibular advancement device is recommended for women with sleep apnea, for men with supine-dependent sleep apneas defined by a lateral apnea-hypopnea index of < 10, and for snorers without sleep apnea. Men who increase in weight during treatment reduce their chance of treatment success and are advised to be followed up with a new sleep apnea recording with the device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sleep disordered breathing.

A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea. Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea. advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Assessment of upper airway dynamics in awake sleep apnea patients wi...

متن کامل

Sleep-disordered breathing.

A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea. Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea. advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Assessment of upper airway dynamics in awake sleep apnea patients wi...

متن کامل

The effect of a mandibular advancement device on apneas and sleep in patients with obstructive sleep apnea.

OBJECTIVE To evaluate the effects of a mandibular advancement device on apneas and sleep in mild, moderate, and severe obstructive sleep apnea. DESIGN Prospective study. SUBJECTS Forty-four of 47 patients included. INTERVENTION Individually adjusted mandibular advancement devices. MEASUREMENTS Polysomnographic sleep recordings for 1 night without the device and 1 night with it, with a m...

متن کامل

Short-term efficacy of mandibular advancement splint in treatment of obstructive sleep apnea-hypopnea syndrome.

OBJECTIVE The aim of the present study was to determine the short-term efficacy of treatment for snoring and obstructive sleep apnea-hypopnea syndrome (OSAHS) using a mandibular advancement splint. METHODS The sample comprised 20 patients (13 men and 7 women; mean age = 48 years; mean body mass index = 27.07) with OSAHS. Polysomnograms were performed before and 60 days after mandibular advanc...

متن کامل

Mandibular advancement device in patients with obstructive sleep apnea : long-term effects on apnea and sleep.

STUDY OBJECTIVES To evaluate the long-term effects on apneas and sleep and the tolerability of a mandibular advancement device in patients with obstructive sleep apnea. DESIGN Prospective study. SETTING Department of Respiratory Medicine, University Hospital, Umeå, Sweden. PATIENTS Thirty-three consecutively treated patients. INTERVENTIONS Individually adjusted mandibular advancement de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 125 4  شماره 

صفحات  -

تاریخ انتشار 2004