Statistical model for diffusion attenuated MR signal.
نویسندگان
چکیده
A general statistical model that can describe a rather large number of experimental results related to the structure of the diffusion-attenuated MR signal in biological systems is introduced. The theoretical framework relies on a phenomenological model that introduces a distribution function for tissue apparent diffusion coefficients (ADC). It is shown that at least two parameters--the position of distribution maxima (ADC) and the distribution width (sigma)--are needed to describe the MR signal in most regions of a human brain. A substantial distribution width, on the order of 36% of the ADC, was found for practically all brain regions examined. This method of modeling the MR diffusion measurement allows determination of an intrinsic tissue-specific ADC for a given diffusion time independent of the strength of diffusion sensitizing gradients. The model accounts for the previously found biexponential behavior of the diffusion-attenuated MR signal in CNS.
منابع مشابه
Diffusion-Weighted MR Imaging in Biopsy-Proven Creutzfeldt-Jakob Disease
OBJECTIVE To compare conventional and diffusion-weighted MR imaging in terms of their depiction of the abnormalities occurring in Creutzfeldt-Jakob disease. MATERIALS AND METHODS We retrospectively analyzed the findings of conventional (T2-weighted and fluid-attenuated inversion recovery) and diffusion-weighted MR imaging in four patients with biopsy-proven Creutzfeldt-Jakob disease. The sign...
متن کاملA novel tensor distribution model for the diffusion-weighted MR signal
Diffusion MRI is a non-invasive imaging technique that allows the measurement of water molecule diffusion through tissue in vivo. The directional features of water diffusion allow one to infer the connectivity patterns prevalent in tissue and possibly track changes in this connectivity over time for various clinical applications. In this paper, we present a novel statistical model for diffusion...
متن کاملروشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملمشخصه های آماری ذرات ضبط مغناطیسی
In magnetic recording media, the remanent magnetization loop, Mr(H)has some parameters, which explain the prperties of the medium in view of the storage density and signal-to-noise ratio. It is necessary to find the mechanism of Mr variations from the statistical characteristics of the system. We have prepared samples of single-domain ascicolar iron particles with 0.3 length, and the oriented...
متن کاملDiffusion and perfusion MRI findings of the signal-intensity abnormalities of brain associated with developmental venous anomaly.
BACKGROUND AND PURPOSE Developmental venous anomalies are the most common intracranial vascular malformation. Increased signal-intensity on T2-FLAIR images in the areas drained by developmental venous anomalies are encountered occasionally on brain imaging studies. We evaluated diffusion and perfusion MR imaging findings of the abnormally high signal intensity associated with developmental veno...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 50 4 شماره
صفحات -
تاریخ انتشار 2003