Key words: capillary-viscometer, viscosity function, Newton-Raphson procedure, genetic algorithm

نویسندگان

  • HERBERT W. MÜLLNER
  • JOSEF EBERHARDSTEINER
  • ANDRÉ WIECZOREK
چکیده

This contribution gives an overview about new procedures for the parameter identification for the material characterisation of rubber blends. They are based on a Newton-Raphson procedure and a genetic algorithm. As basis serves an experimental investigation of the viscous properties of rubber blends by means of a capillary-viscometer. Because of simultaneous consideration of wall slippage, temperature and of the die swell, the proposed material characterisation is represented by a coupled system of nonlinear equations. Describing their solutions requires a numerical integration algorithm. For this purpose a generalized Newton-Raphson scheme has been adopted. The verification of the developed parameter identification was done by means of another approach which is based on a genetic algorithm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S0956-5663(01)00314-1

A newly designed mass-detecting capillary viscometer is extended to measure the viscosity of whole blood over a range of shear rates without the use of anticoagulants in a clinical setting. In the present study as proof of principle, a single measurement of liquid-mass variation with time replaces the flow rate and pressure drop measurements that are usually required for the operation of a capi...

متن کامل

Automated measurement of plasma viscosity by capillary viscometer.

Plasma viscosity has several advantages over the erythrocyte sedimentation rate as a measurement of an acute phase response of more than 24 hours' duration. A new capillary viscometer (Coulter Viscometer II), which gives an automated measurement of plasma viscosity, was compared with the selected manual method (Harkness viscometer) of the International Committee for Standardization in Haematolo...

متن کامل

Studies on blood viscosity during extracorporeal circulation.

Blood viscosity was studied during extracorporeal circulation by means of a cone in cone viscometer. This rotational viscometer provides sixteen kinds of shear rate, ranging from 0.05 to 250.2 sec-1 • Merits and demerits of the equipment were described comparing with the capillary viscometer. In experimental study it was well demonstrated that the whole blood viscosity showed the shear rate dep...

متن کامل

Procedure to Evaluate the Shear Rate Profile and the Apparent Viscosity of Non-newtonian Fluids in the Falling Cylinder Viscometer

−− The falling cylinder viscometer (FCV) is a reliable instrument to quantify the viscosity of Newtonian fluids. Nevertheless, when nonNewtonian fluids are tested in this device, difficulties appear to determine the apparent viscosity. Thus, conventional rheometric calculations cannot be applied directly to experimental data provided by the FCV in order to obtain the apparent viscosity function...

متن کامل

Model Reference Neural Predictive Controller for Induction Motor Drive

In this paper an accurate nonlinear model of induction motor using an artificial neural network (ANN) is given. This modeling technique is done by using the data from the system inputs/outputs information without requiring the knowledge about machine parameters. The ANN training is carried out off-line using the Levenberg-Marquardt algorithm. Then, the proposed neural network model is used as p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006