A Nested Dual Frequency Birdcage/Stripline Coil for Sodium/Proton Brain Imaging at 7T
نویسندگان
چکیده
Introduction: Dual tuned sodium/proton coils are valuable for multi-nuclear magnetic resonance imaging and spectroscopy. Due to low sodium content in the body and its low gyromagnetic ratio, the critical design aim for a sodium/proton coil is to maximize sodium sensitivity and homogeneity while maintaining adequate proton sensitivity. This has previously been achieved using a dual-tuned birdcage coil (1) incorporating high-impedance “trap” circuits that permit dual resonance (2,3). Compared to a single tuned coil, this approach has yielded detectors with 80-90% efficiency at the low resonance frequency and 40-50% efficiency at the high resonance frequency. While this design has the benefit of packaging both coils on a single structure, it requires numerous identical traps that can make tuning an arduous task, especially for high field applications. High field is particularly beneficial for sodium imaging because the high field signal-to-noise advantage helps to compensate for the inherently weak sodium signal. Another proposed approach is a stripline array with alternating elements tuned to different frequencies (4). Rather than implement a dual-tuned coil, we explored a nested-coil configuration for sodium/proton imaging at 7T with the goal of maintaining as much SNR performance as possible at the sodium frequency. A traditional single-tuned birdcage coil was used for sodium excitation and detection and an eight-channel stripline array was used for proton. Striplines have become popular for high-field MRI due to their spatially distinct sensitivity pattern, self-contained E-fields, and relatively low inter-element coupling (5). In this dual frequency application, we hypothesized that the high pass birdcage would have little interaction with the stripline elements. Correspondingly, particular attention was given to the effect of the proton striplines on the performance of the sodium birdcage. Methods: For the sodium side, a standard high pass birdcage coil with eight 19cm rungs was built on a cylindrical acrylic former with 27.9cm diameter (Fig. 1). The high pass design was selected since the high-order birdcage modes occur at frequencies below the 78MHz uniform mode, and interaction with 297MHz proton coil should be minimized (Fig. 2). Birdcage resonance at 78.6MHz was achieved by inserting 33pF capacitors at 16 locations along the endrings. In transmit mode, the birdcage was driven in quadrature through a 90° hybrid. In receive mode, the signals from each quadrature channel were fed to independent preamplifiers (6). The isolated sodium birdcage was characterized on the bench by measuring the loaded (1890mL water phantom with 7.1g NiSO4×6H2O and 9.5g NaCl) and unloaded quality factor (Q) and on a whole-body scanner (MAGNETOM 7T, Siemens Healthcare, Erlangen, Germany) by measuring the RF transmit voltage required for a 90° flip angle with a 500μs hard pulse and the signal-to-noise ratio (SNR) of a gradient echo image in the transverse plane in the center of the coil. Complex k-space signal and noise from both channels were used to generate the combined image with optimal SNR. These measurements were repeated after introduction of the proton striplines. Eight proton striplines were centered between the birdcage rungs and mounted on the acrylic former. The striplines were built on 15x4x1.3cm teflon bars with ground planes formed using 4cm wide copper tape and sidewalls with 1.3cm height to reduce inter-element coupling (4). The active element was formed using 14x2cm copper tape. Two capacitors of approximately 6.8 pF and 8.2 pF were distributed at opposing ends of the striplines to achieve resonance at 297.2 MHz. Separate baluns tuned to proton and sodium frequencies were utilized to reduce currents on the coaxial cable shields. Excitation was provided via an eight-way power splitter consisting of a three stage cascade of seven Wilkinson power dividers. The stripline array was driven in a birdcage-like manner, with 45° phase delays between each element corresponding to their azimuthal position. Signals received from each element were fed to independent preamplifiers via coaxial cable of appropriate length for preamplifier decoupling (7). The stripline array was characterized by measuring the loaded (7300mL water phantom with 9.1g NiSO4×6H2O and 19.1g NaCl) and unloaded Q, RF transmit voltage required to achieve a 90° flip angle with a 1ms hard pulse and the signalto-noise ratio (SNR) in the center of the phantom. Scanner measurements were repeated using a commercially available quadrature head coil with 28cm diameter (Invivo Corp.) This study was approved by our local institutional review board and healthy volunteers were scanned after obtaining informed written consent. Results: The resonance frequency of the sodium birdcage increased to 80.8MHz in the presence of the proton striplines due to shielding, requiring an additional 2pF at each location to pull its resonance down to 78.6MHz. This shielding resulted in a 20% increase in the RF voltage needed for the birdcage to create a 90° flip and an 8% reduction in SNR (Table 1). Fig. 3 shows 3-plane phantom images demonstrating the typical homogeneous birdcage sensitivity pattern. In vivo sodium images are shown in Fig. 4. The stripline array provided good coverage and adequate sensitivity for B0 shimming and anatomical reference imaging (Fig. 5). The SNR of the stripline array was approximately 68% that of the commercial volume coil. Discussion: The nested sodium/proton coil proved to be a feasible alternative to the standard trap-based method for dual frequency imaging. There was little interaction between the sodium birdcage and proton stripline, resulting in near-maximum sodium sensitivity. This characteristic simplified construction as the sodium and proton coil could be tuned independently. Stripline sensitivity may be improved by up to 30% by optimizing the substrate thickness (8), potentially providing similar sensitivity as the commercial coil. References: 1) Hayes, et al. JMR 1985. 2) Schnall, et al. JMR 1985. 3) Shen, et al. MRM 1997. 4) Xie, et al. ISMRM High Field MR 2007. 5) Adriany, et al. MRM 2008. 6) Sorgenfrei, Edelstein. MRM 1996. 7) Roemer, et al. MRM 1990. 8) Akgun, et al. ISMRM 2009. Table 1. Coil performance. Sodium BC (Isolated) Sodium BC (with Proton Striplines) Proton Striplines Commercial Head Coil Unloaded Q 403 365 320 Loaded Q 30 31 190 90° Tx voltage 220 265 125 60 Phantom SNR 12.1 11.1 43.4 63.8
منابع مشابه
Design and Simulation of a Birdcage Coil using CST Studio Suite for Application at 7T
This work describes the study of coil for Magnetic Resonance Imaging (MRI) application. Concretely, the principal objective is the design of a birdcage coil (RF coil) to use in a 7 Tesla scanner. More strength field has a better SNR and increased chemical shift effects, improving spectral fat suppression and spectroscopy. Moreover, a better SNR increases the spatial resolution or reduces the im...
متن کاملSodium MR imaging of kidney and other abdominal organs using a dual-tuned body RF coil at 7T
[Introduction] In vivo sodium MR imaging is promising because it is capable of providing physiologic and metabolic tissue information beyond conventional proton MR imaging. Unfortunately, the image quality of sodium MR imaging is poor when compared with proton imaging because of the low SNR due to the inherent low biological sodium content and low MR sensitivity. The low SNR problem may be alle...
متن کاملUltra-High Field MRI of Primary Brain Tumors: Contrast and Resolution
INTRODUCTION Primary brain tumors are well-known for their heterogeneous presentation and/or therapeutic response which often requires higher imaging specificity than that provided by conventional MRI scans. In the setting of this disease, imaging of primary brain tumors at Ultra-High magnetic Fields (UHF, >3 Tesla) magnetic resonance imaging (MRI) has tremendous appeal due to the expected impr...
متن کامل23Na/1H MR imaging of female pelvis at 7T using a dual-tuned multi-channel body coil
[Introduction] MR imaging of the female pelvis is a commonly performed clinical examination which allows for a superb delineation of various pathologies involving reproductive organs. In addition to anatomic imaging, physiologic imaging of female pelvis may provide new insights into pathological conditions. In this regard, in vivo sodium MR imaging is highly attractive because it is capable of ...
متن کاملA 7T 8 channel transmit-receive dipole array for head imaging: dipole element and coil evaluation
Target audience: Radiofrequency (RF) engineers, anyone interested in high field RF coils, parallel transmit or high field brain imaging. Introduction: Electric dipole antennas are seeing increasing use for 7T MR imaging. They differ from conventional surface coil loops in many ways. With 8 elements surrounding a body sized tissue equivalent phantom and array of dipole antennas can achieve highe...