Subcutaneous Implantable Cardioverter Defibrillators Implantation Without Defibrillation Threshold Testing: A Single Center Experience
نویسندگان
چکیده
Background Subcutaneous implantable cardioverter defibrillator (S-ICD) system has been proven to be an effective therapy for prevention of sudden cardiac death (SCD) in selected patients. Although the Shockless IMPLant Evaluation (SIMPLE) trial has shown that defibrillation threshold (DFT) testing is not necessary for transvenous ICD (TV-ICD) systems, it is still recommended for S-ICD systems. We aimed to study the efficacy and safety of S-ICD implantation without DFT in our Heart Center with the comparison of S-ICD patients' outcome to those with a single chamber TV-ICD without DFT in the same period. Methods A retrospective analysis of patients underwent S-ICD without DFT from December 2014 to May 2016 with the comparison to single chamber TV-ICD patients implanted during the same period. Results Thirty consecutive patients (23 males (76.7%); mean age 41 ± 13 years; mean left ventricular ejection fraction 30±12%) received a S-ICD for primary (25 patients, 83.3%) or secondary prevention (five patients, 16.7%) of SCD. During a mean follow-up of 710.6 ± 190 days, three patients received 38 appropriate ICD shocks (90.5%), and two patients received four inappropriate shocks (9.5%). There were two mortalities (6.7%): one cardiac and one non-cardiac. When compared to 30 consecutive who received a single chamber TV-ICD during the same period, there was no significant difference in mortality. Conclusions Implantation of S-ICD using intermuscular approach without DFT seems to be safe and effective. Data from large S-ICD registries with long-term follow-up, and preferably randomized controlled studies, are needed to confirm this finding.
منابع مشابه
Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).
BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...
متن کاملAzygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement
Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.
متن کاملSubcutaneous ICD lead position affects defibrillation threshold
Introduction Subcutaneous implantable cardioverter-defibrillators (S-ICD) provide an alternative to traditional transvenous implantable cardioverter-defibrillators (TV-ICD) and avoid complications associated with intravascular access and leads. They are highly effective in detecting and treating ventricular arrhythmias, with comparable inappropriate shock rates. Use of S-ICD is anticipated to i...
متن کاملSuccessful intermuscular implantation of subcutaneous implantable cardioverter defibrillator in a Japanese patient with pectus excavatum
The entirely subcutaneous implantable cardioverter-defibrillator (ICD) system was developed to provide a life-saving defibrillation therapy that does not affect the heart and vasculature. The subcutaneous ICD is preferred over the transvenous ICD for patients with a history of recurrent infection presenting major life-threatening rhythms. In this case report, we describe the first successful in...
متن کاملShoulder Joint Dislocation as an Unusual Complication of Defibrillation Threshold Testing Following Subcutaneous Implantable Cardioverter-Defibrillator Implantation
A 53-year-old man underwent implantation of a totally subcutaneous ICD (S-ICD; Boston Scientific). He was positioned supine, with the left arm abducted, externally rotated (i.e. palm up) and strapped to the arm extender. The generator was placed in the left mid-axillary line along the 5th-6th intercostal spaces and the defibrillation coil was tunneled anterior to the sternum. Defibrillation thr...