Horizontal versus vertical orientation of the loop for tension band wiring of transverse patella fractures.

نویسندگان

  • Sang Ki Lee
  • Yoon Sub Hwang
  • Won Sik Choy
چکیده

Conventional operative treatments of patella fractures are frequently associated with implant failure or displacement. Recent biomechanical studies showed that the orientation of the wire loop and the site of the wire twist can affect the fixation strength. The purpose of this study was to compare the clinical outcome of the tension band technique with loops in different orientations and different knot positions. For this retrospective study, 72 patella fractures (71 patients) were fixed with figure-of-eight configurations in combination with 2 K-wires. Patients were divided into 3 groups according to the orientation of tension band construct. A total of 40 patella fractures were placed with figure-of-eight configurations in a vertical orientation either with 1 wire twist (group 1; 16 patella fractures) or with 2 wire twists at the adjacent corners (group 2; 24 patella fractures). Thirty-two patella fractures were placed with figure-of-eight configurations in a horizontal orientation with 2 wire twists at the adjacent corners (group 3). Range of motion, complication rates, and knee scoring scales (Hospital for Special Surgery and Lysholm) were assessed during serial follow-up. Satisfactory reductions were achieved in all groups, but functional results in the early stage were different. Group 3 had better Hospital for Special Surgery and Lysholm scores at 3 months postoperatively; however, at 6 months and 1 year postoperatively, all groups had similar scores. At the 1-year follow-up, all groups achieved acceptable flexion and range of motion. The overall complication rate was lower in the horizontal group (12.5%). Placing the figure-of-eight tension band construct in a horizontal orientation can provide functional benefits in the early stage after patella fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella

PURPOSE Tension band wiring is commonly used for fixation of simple transverse fractures. The popular configuration is parallel Kirschner wires (K-wires) and a stainless steel wire loop placed in a vertically oriented figure-of-8. METHODS We used a wooden model of a patella with a midway transverse fracture and compared four different types of fixation. The first construct had a vertical figu...

متن کامل

Rehabilitation of Isolated Patella Fracture: A Case Report

Fracture of the patella is a common injury among adults having higher prevalence among males population. The mechanism of injury involves direct and indirect mechanisms. The most common fracture pattern occurring is the transverse fracture followed by comminuted and vertical fractures. Treatment of patellar fractures depends on fracture type, integrity of extensor mechanism and size of fragment...

متن کامل

Percutaneous tension band wiring for patellar fractures.

PURPOSE To evaluate outcome of percutaneous tension band wiring for transverse fractures of the patella. METHODS 16 men and 7 women aged 27 to 65 (mean, 40) years underwent percutaneous tension band wiring for transverse fractures of the patella with a displacement of >3 mm. Pain, operating time, mobility, functional score, and complications were evaluated. RESULTS 20 patients underwent suc...

متن کامل

Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring

Aims: To evaluate the effectiveness and safety of anterior tension band wiring technique using two cannulated cancellous screws in patients with transverse (AO34-C1) or transverse with mildly comminuted (AO34-C2) patellar fractures. Materials and Methods: This is a prospective study of 25 patients with transverse fracture or transverse fracture with mildly comminuted patella fractures. All the ...

متن کامل

Modified Tension Band Wiring in Adult Distal Humeral Fracture Types A2 and C1

Background: Distal humeral fractures accounts for approximately 2% of all fractures and nearly one-third of humeralfractures in adults. In this regard, Modified Tension Bind Wiring (MTBW) technique was used for the fixation of the distalhumeral fractures type A2 and C1 (AO) to evaluate the early movement and complications of the patients.Methods: This study was conducted on 25...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2014