BIS monitoring to prevent awareness during general anesthesia.
نویسندگان
چکیده
BACKGROUND Unexpected awareness is a rare but well-described complication of general anesthesia that has received increased scientific and media attention in the past few years. Transformed electroencephalogram monitors, such as the Bispectral Index monitor, have been advocated as tools to prevent unexpected recall. METHODS The authors conducted a power analysis to estimate how many patients would be needed in an appropriately powered study to demonstrate the Bispectral Index monitor reduces awareness, as well as a cost analysis to assess the cost of using the monitor for this purpose alone. RESULTS If unexpected recall is rare (1 in 20,000), it will require a large study to demonstrate that the monitor reduces awareness (200,000-800,000 patients), and the cost of using it for this purpose alone would be high ($400,000 per case prevented). If awareness is common (1 in 100), then the number of patients needed in a study to demonstrate that the monitor works becomes tractable (1,000-4,000 patients), and the cost of using the monitor for this purpose alone becomes lower ($2,000 per case prevented). Because there are reported cases of awareness despite Bispectral Index monitoring, the authors are certain that the effectiveness of the monitor is less than 100%. As the performance of the monitor decreases from 100%, the size of the study needed to demonstrate that it works increases, as does the cost of using it to prevent awareness. CONCLUSION The contention that Bispectral Index monitoring reduces the risk of awareness is unproven, and the cost of using it for this indication is currently unknown.
منابع مشابه
بررسی میزان آگاهی (awareness) در طی بی هوشی عمومی جهت سزارین در بیمارستان های آموزشی دانشگاه علوم پزشکی مازندران در سال 83-84
Background and purpose: Awareness during general anesthesia is a frightening experience that often causes patients to panic and feel helpless even when there is no pain and no feel of body movement and manipulation by the surgeon. Awareness monitoring is still complicated and controversial. Now a days this is based on electroencephalography data such as the bispectral index (BIS) or spectr...
متن کاملThe Ability of Bispectral-Guided Management Compared to Routine Monitoring for Reflecting Awareness Rate in Patients Undergoing Abdominal Surgery
BACKGROUND Awareness during general anesthesia in different types of surgery is an important described adverse event. Bispectral (BIS) monitoring is one of the recent techniques proposed to monitor the depth of anesthesia. OBJECTIVES The present study tested the hypothesis that the awareness rate and changes in hemodynamic parameters within anesthesia would be lower in patients allocated to B...
متن کاملDo we need bispectral index monitoring during total intravenous anesthesia for lumbar discectomies?
The aim of this study was to investigate the effect of bispectral index (BIS) monitoring on hemodynamic parameters, drug consumption and awareness during total intravenous anesthesia (TIVA) with remifentanil and propofol in lumbar discectomies. After institutional ethical committee approval, ASAI-II 56 patients were divided as control and BIS groups. Anesthesia was induced by bolus remifentanil...
متن کاملBispectral index monitoring prevent awareness during total intravenous anesthesia: a prospective, randomized, double-blinded, multi-center controlled trial.
BACKGROUND Awareness is a serious complication of general anesthesia. In China, the incidence of intraoperative awareness was 1% in patients undergoing total intravenous anesthesia (TIVA). In this study, we compared the incidence of awareness between Bispectral index (BIS)-guided and routine TIVA protocol and evaluated the effect of BIS on preventing awareness. METHODS A prospective, randomiz...
متن کاملHow do you use bispectral index effectively for preventing re-awareness during general anesthesia?
Corresponding author: Yun Hong Kim, M.D, Ph.D., Department of Anesthesiology and Pain Medicine, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Pyeong-dong, Jongno-gu, Seoul 110-746, Korea. Tel: 82-2-2001-2315, Fax: 82-2-2001-2326, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial Licen...
متن کاملEvaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 94 3 شماره
صفحات -