Correction of the Low-Frequency Physiological Noise in the Resting State BOLD fMRI - Effect on the ICA Default-Mode Analysis at 1.5T
نویسندگان
چکیده
Introduction: In the studies of low-frequency resting state networks (RSN) the impact of aliased physiologic noise has been a persistent source of criticism and uncertainty in the interpretation of the results. More recently, lagged estimates of the low-frequency physiological noise fluctuations (respiratory (1) and cardiac (2)) have been shown to explain notable signal variance in the regression analysis of the RSNs, affecting particularly the so called default mode network (DMN). DMN spatially overlaps with regions significantly affected by physiologic low-frequency fluctuations and they occur at similar frequencies. Exact physiological mechanism linking respiratory and cardiac fluctuations to BOLD fMRI is not yet known, but e.g. fluctuations in arterial CO2 due to breath and pulse rate changes cause BOLD signal changes. Thus resting state fMRI analysis is complicated by unknown low-frequency noise sources, although at 1.5T physiologic noise is less pronounced compared to 3T scanners. Datadriven independent component analysis (ICA) can, in theory, separate spatiotemporally independent signal sources, like noise processes from neural processes, but capability has not been determined in the frame of RSNs, although at least task related independent components (IC) have been shown to be highly repeatable using odd and even timepoints of the original timeseries as input data (3). In this study, the relevance of the physiological noise correction for the ICA in detecting RSNs and especially DMN, is of interest. Methods: Subjects and imaging: Twelve healthy adults were imaged on GE 1.5T HDX scanner equipped with an 8-channel head coil. Volunteers were instructed to rest their eyes closed for the 7 min 24 s long BOLD fMRI scanning (GR-EPI, TR 1764 ms, TE 40 ms, flip angle 90, 4x4x4 mm voxel). Heart beats were recorded using photoplethysmograph and respiration data was measured using respiratory belt, both equipment provided by the scanner manufacturer. Pre-processing: AFNI was used for motion correction and physiologic noise correction of the data. Dataset that is only motion corrected will be referred as noCorr and dataset that is also corrected for physiologic noise as physCorr. Physiologic noise correction constitutes of three different methods: 1) RETROICOR (4); slightly modified version of RETROICOR implemented in AFNI 3dretroicor function was performed. 2) Respiration volume per time (RVT) (1) using eight lagged regressors (from -6 TR (-10,5 s) to +15 TR (+26,5 s)) in deconvolution. 3) Correction for cardiac rate low-frequency fluctuation (2) using five lagged regressors (from 0 TR to + 15 TR (26.5 s)) in deconvolution. Three subjects had to be excluded from analysis due to too many spurious pulses (> 5%) (2). Altogether eight respiratory and five cardiac estimates were then regressed out from the BOLD timeseries and remaining residual constituted the physCorr data. Analysis: Spatial ICA (FSL MELODIC) was performed for both noCorr data and physCorr data. Estimation of the number of components was performed for noCorr data. This estimate was used also for the physCorr data, since dimensionality estimation for physCorr data can result in several times more ICs to be calculated compared to noCorr. This is due to the regression analysis in the prior preprocessing that removes variance from the data. However, from the ICA viewpoint it seems to break the spatiotemporal integrity of the independent components. DMN ICs were visually identified from the noCorr ICA results and for every subject the best matching DMN pair from the physCorr ICA results was selected with the help of spatial cross-correlation. Additionally ICA was performed for the data that was obtained as a fit for physiological regressors to see what was regressed out. After spatial smoothing and normalization in FSL, unthresholded z-score DMN maps were fed into Wilcoxon signed-rank test to perform non-parametric paired comparison on group-level between the noCorr and physCorr DMNs. Results and discussion: DMN IC maps did not change significantly after physiological correction as illustrated by DMNs of the four representative subjects in Fig 1. On the other hand, performing ICA for the physiological regressors’ regression fit (ICA on fMRI data noCorr minus physCorr) revealed IC maps with similar DMN characteristics (Fig. 1, bottom row) but weighted on the lower frequency than noCorr or physCorr DMN. Thus, regressing out lagged low-frequency respiratory and cardiac estimates, removes especially the low-frequency contribution of the respiratory and cardiac related noise sources from the DMN leaving spatial appearance quite similar. Difference between noCorr and physCorr DMN was found to be not statistically significant. In Fig 2, is shown the most significant difference (peak value t = 2.66) where physCorr DMN was greater than noCorr. Conclusion: Necessity of the physiological noise correction in fMRI analysis depends on the study focus; in spatial analysis ICA performance does not significantly benefit of physiological noise correction at 1.5T. If a study concerns the time or frequency domain of the RSNs, physiological correction would be benefitial.
منابع مشابه
Brain Activity Map Extraction of Neuromyelitis Optica Patients Using Resting-State fMRI Data Based on Amplitude of Low Frequency Fluctuations and Regional Homogeneity Analysis
Introduction: Neuromyelitis Optica (NMO) is a rare inflammatory disease of the central nervous system which generally affecting the spinal cord and optic nerve. Damage to the optic nerve can result in the patient's dim vision or even blindness, while the spinal cord damage may lead to sensory and motor paralysis and the weakness of the lower limbs in the patient. Magnetic Reson...
متن کاملEffect of Physiological noise on Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field
Introduction: Functional MRI methods have been used to study sensorimotor processing in the brain and the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as signifi...
متن کاملEffect of Physiological Noise on Thoraco-lumbar Spinal Cord FMRI in 3T Magnetic Field
Introduction: Functional MRI methods have been used to study sensorimotor processing in the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from the physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as significant sources of noise, especi...
متن کاملBeyond Noise: Using Temporal ICA to Extract Meaningful Information from High-Frequency fMRI Signal Fluctuations during Rest
Analysis of resting-state networks using fMRI usually ignores high-frequency fluctuations in the BOLD signal - be it because of low TR prohibiting the analysis of fluctuations with frequencies higher than 0.25 Hz (for a typical TR of 2 s), or because of the application of a bandpass filter (commonly restricting the signal to frequencies lower than 0.1 Hz). While the standard model of convolving...
متن کاملCan apparent resting state connectivity arise from systemic fluctuations?
It is widely accepted that the fluctuations in resting state blood oxygenation level dependent (BOLD) functional MRI (fMRI) reflect baseline neuronal activation through neurovascular coupling; this data is used to infer functional connectivity in the human brain during rest. Consistent activation patterns, i.e., resting state networks (RSN) are seen across groups, conditions, and even species. ...