Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears.

نویسندگان

  • Charles Milchteim
  • Eric A Branch
  • Ty Maughon
  • Jay Hughey
  • Adam W Anz
چکیده

BACKGROUND Longitudinal meniscus tears are commonly encountered in clinical practice. Meniscus repair devices have been previously tested and presented; however, prior studies have not evaluated repair construct designs head to head. This study compared a new-generation meniscus repair device, SpeedCinch, with a similar established device, Fast-Fix 360, and a parallel repair construct to a crossed construct. Both devices utilize self-adjusting No. 2-0 ultra-high molecular weight polyethylene (UHMWPE) and 2 polyether ether ketone (PEEK) anchors. HYPOTHESIS Crossed suture repair constructs have higher failure loads and stiffness compared with simple parallel constructs. The newer repair device would exhibit similar performance to an established device. STUDY DESIGN Controlled laboratory study. METHODS Sutures were placed in an open fashion into the body and posterior horn regions of the medial and lateral menisci in 16 cadaveric knees. Evaluation of 2 repair devices and 2 repair constructs created 4 groups: 2 parallel vertical sutures created with the Fast-Fix 360 (2PFF), 2 crossed vertical sutures created with the Fast-Fix 360 (2XFF), 2 parallel vertical sutures created with the SpeedCinch (2PSC), and 2 crossed vertical sutures created with the SpeedCinch (2XSC). After open placement of the repair construct, each meniscus was explanted and tested to failure on a uniaxial material testing machine. All data were checked for normality of distribution, and 1-way analysis of variance by ranks was chosen to evaluate for statistical significance of maximum failure load and stiffness between groups. Statistical significance was defined as P < .05. RESULTS The mean maximum failure loads ± 95% CI (range) were 89.6 ± 16.3 N (125.7-47.8 N) (2PFF), 72.1 ± 11.7 N (103.4-47.6 N) (2XFF), 71.9 ± 15.5 N (109.4-41.3 N) (2PSC), and 79.5 ± 25.4 N (119.1-30.9 N) (2XSC). Interconstruct comparison revealed no statistical difference between all 4 constructs regarding maximum failure loads (P = .49). Stiffness values were also similar, with no statistical difference on comparison (P = .28). CONCLUSION Both devices in the current study had similar failure load and stiffness when 2 vertical or 2 crossed sutures were tested in cadaveric human menisci. CLINICAL RELEVANCE Simple parallel vertical sutures perform similarly to crossed suture patterns at the time of implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison Between the Cruciate Suture and a Single Vertical Suture Used for Arthroscopic Meniscal Repair: Letter to the Editor

Dear Editor: I recently read with interest the article titled “Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears” by Milchteim et al published in the April 2016 issue of the Orthopaedic Journal of Sports Medicine (OJSM). The article is great and adds a lot to the current available knowledge, and I believe that it is of great interest to the readers o...

متن کامل

Biomechanical testing of transcapsular meniscal repair

BACKGROUND All of previous biomechanical studies on meniscal repair have examined the meniscus itself without synovial membrane and capsule, although in the clinical setting, the meniscal repair is generally performed including capsule. Therefore, biomechanical properties of transcapsular meniscal repair are unclear. Thus, this study aimed to clarify the biomechanical properties of transcapsula...

متن کامل

Cyclic Testing of Flexible All-Inside Meniscus Suture Anchors

Arthroscopic inside-out and outside-in meniscus repair techniques are technically demanding. The need for additional incisions with the risk of iatrogenic neurovascular damage can lead to prolonged intraoperative and tourniquet time and can thereby increase morbidity and anesthesia costs. To overcome these disadvantages, all-inside repair devices were developed. Simple insertion of these rigid ...

متن کامل

Augmented repair of radial meniscus tear with biomimetic electrospun scaffold: an in vitro mechanical analysis

BACKGROUND Large radial tears that disrupt the circumferential fibers of the meniscus are associated with reduced meniscal function and increased risk of joint degeneration. Electrospun fibrous scaffolds can mimic the topography and mechanics of fibrocartilaginous tissues and simultaneously serve as carriers of cells and growth factors, yet their incorporation into clinically relevant suture re...

متن کامل

Altered tibiofemoral contact mechanics due to lateral meniscus posterior horn root avulsions and radial tears can be restored with in situ pull-out suture repairs.

BACKGROUND An avulsion of the posterior root attachment of the lateral meniscus or a radial tear close to the root attachment can lead to degenerative knee arthritis. Although the biomechanical effects of comparable injuries involving the medial meniscus have been studied, we are aware of no such study involving the lateral meniscus. We hypothesized that in situ pull-out suture repair of latera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopaedic journal of sports medicine

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2016