Comparing methods of clinical measurement: reporting standards for bland and altman analysis.
نویسندگان
چکیده
UNLABELLED In this era of medical technology assessment and evidence-based medicine, evaluating new methods to measure physiologic variables is facilitated by standardization of reporting results. It has been proposed that assessing repeatability be followed by assessing agreement with an established technique. If the "limits of agreement" (mean bias +/- 2SD) are not clinically important, then one could use two measurements interchangeably. Generalizability to larger populations is facilitated by reporting confidence intervals. We identified 44 studies that compared methods of clinical measurement published during 1996 to 1998 in seven anesthesia journals. Although 42 of 44 (95.4%) used the limits of agreement methodology for analysis, several inadequacies and inconsistencies in reporting the results were noted. Limits of agreement were defined a priori in 7.1%, repeatability was evaluated in 21.4%, and relationship (pattern) between difference and average was evaluated in 7.1%. Only one of the articles reported confidence intervals. A computer macro for the Minitab statistical package (State College, PA) is described to facilitate reporting of Bland and Altman analysis with confidence intervals. We propose standardization of nomenclature in clinical measurement comparison studies. IMPLICATIONS A literature review of anesthesia journals revealed several inadequacies and inconsistencies in statistical reports of results of comparison studies with regard to interchangeability of measurement methods. We encourage journal editors to evaluate submissions on this subject carefully to ensure that their readers can draw valid conclusions about the value of new technologies.
منابع مشابه
Application of Bland-Altman Method in Comparing Transrectal and Transabdominal Ultrasonography for Estimating Prostate Volume
Background: Estimating prostate volume using less invasive transabdominal ultrasonography (TAUS) instead of transrectal ultrasonography (TRUS) is of interest in terms of identifying their agreement level. Previous reports on this subject, applied general correlation coefficient as the level of agreement. This study uses Bland-Altman method to quantify TAUS and TRUS agreement on estimating prost...
متن کاملCalculation of plasma chloride levels using blood gas measurements
Objective: Chloride is the major plasma anion. There are several methods available for the determination of serum chloride levels. Unfortunately these methods are sometimes not available in the urgent setting where values are needed. Here we describe...
متن کاملاعتبارسنجی روشهای اندازهگیری طول کانال دندان: یک مطالعه روش شناختی
Background and Aims: Acurate measurements of variables are crucial in epidemiological studies. Therefore, even the best design cannot prevent bugs caused due to the lack of reliability and validity measurement in studies. The aim of this study is to determine the validity of teeth-canal measurement. Materials and Methods: This methodological study used available data of patients referred t...
متن کاملEstimation of Fetal Weight by Clinical Methods and Ultrasonography and Comparing With Actual Birth Weight
Introduction: Assessment of fetal weight is a vital factor in antenatal care, not only in the management of labor and delivery but also in identifying fetal weight disorders. Objective: This study compares the accuracy of clinical methods and ultrasonography in Estimating Fetal Weight (EFW) with Actual Birth Weight (ABW) in term pregnant women. Materials and Methods: This diagnostic test eval...
متن کاملEmbedding equivalence t-test results in Bland Altman Plots visualising rater reliability
ABSTRACT In determining rater (instrument) reliability many techniques are available. A main discrimination between methods is made by the level of measurement (binary, categorical, continuous). Most techniques, such as the Mean Absolute Difference (MAD) or the Intraclass Correlation Analysis (ICC), apply to continuous data. Two other analysis methods are equivalence t-tests (quantitatively det...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesia and analgesia
دوره 90 3 شماره
صفحات -
تاریخ انتشار 2000