Patient reactions and granulocyte degranulation during hemodialysis with cuprophane and polycarbonate membranes. A double-blind study.

نویسندگان

  • B G Danielson
  • R Hällgren
  • P Venge
چکیده

During dialysis with cuprophane or polycarbonate filters, a fall in neutrophil and eosinophil cell counts is observed. Total complement remains unchanged, but C3a increases indicating complement activation. Release of granular granulocyte proteins is observed indicating granulocyte activation. Patient reactions or biochemical findings indicate no significant difference when polycarbonate or cuprophane membranes are used, except perhaps less complement activation with polycarbonate. The biochemical observations may be due to complement activation or cell contact with the membrane.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Citrate anticoagulation does not correct cuprophane bioincompatibility as evaluated by the expression of leukocyte surface molecules.

BACKGROUND Citrate, used for the anticoagulation of the extracorporeal dialysis circuit, reduces ionized calcium by chelation and has been claimed to attenuate dialyser membrane bioincompatibility. Dialysis with complement-activating cuprophane membranes is associated with leukopenia which has been related to an increase in adhesion molecule expression on the surface of circulating leukocytes. ...

متن کامل

Effect of acupressure on constipation in patients undergoing hemodialysis: A randomized double-blind controlled clinical trial

Objective: Constipation is one of the most common digestive problems in patients undergoing hemodialysis. It has a negative effect on quality of life in these patients. As routine treatments are not effective in this regard, complementary therapies may help to overcome this condition. This study aimed to investigate the effect of acupressure on constipation in patients undergoing hemodialysis. ...

متن کامل

Role of bradykinin in anaphylactoid reactions during hemodialysis with AN69 dialyzers.

In vitro experiments have related anaphylactoid reactions in patients treated with angiotensin-converting enzyme (ACE) inhibitors during dialysis with AN69 membranes to excessive bradykinin generation using this negatively charged dialysis membrane. In the present clinical trial plasma bradykinin levels were followed during the early phase of dialysis in 10 patients, not being treated with ACE ...

متن کامل

Postdialysis fatigue: lack of effect of a biocompatible membrane.

Tumor necrosis factor-alpha (TNF-alpha) has been shown to have somnogenic properties. Plasma levels of this cytokine have been found to increase significantly during dialysis with a bioincompatible (cuprophane) membrane in patients with postdialysis fatigue (PDF). We conducted a crossover study with random assignment to ascertain whether a biocompatible membrane might attenuate the increase of ...

متن کامل

Acute effects of hemodialysis on oxidative stress parameters in chronic uremic patients: Comparison of two dialysis membranes

Uremic state and hemobioincompatibility are implicated in subclinical inflammation and oxidative stress and progression of atherosclerosis in the hemodialysis (HD) population. To what extent different dialysis membranes contribute to oxidative stress induced by a dialysis procedure per se is still a subject of debate. Fifteen HD patients and 15 healthy controls were enrolled in this study. Pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood purification

دوره 4 1-3  شماره 

صفحات  -

تاریخ انتشار 1986