Single-bounce monocapillaries for focusing synchrotron radiation: modeling, measurements and theoretical limits.
نویسندگان
چکیده
Single-bounce hollow glass capillaries with ellipsoidal shapes have been used at the Cornell High Energy Synchrotron Source recently for various microbeam experiments, with focal spot sizes from 12 to 23 microm, divergences from 2 to 8 mrad, intensities up to 450 times the intensities of incident X-rays, and working distances up to 55 mm. Simple formulae are developed in this paper to explain capillary performance given the X-ray source size, capillary dimensions and slope errors. Capillary length is optimized for best focusing performance. Capillary fabrication accuracy is reported and capillary X-ray tests confirm the focusing properties expected from formulae. The application of capillaries to third-generation X-ray sources and future energy-recovery linac X-ray sources are discussed.
منابع مشابه
Two-step hard X-ray focusing combining Fresnel zone plate and single-bounce ellipsoidal capillary.
A two-step focusing set-up combining a Fresnel zone plate with an ellipsoidal capillary is presented. It is shown that, in addition to the anticipated gain in flux, the employment of the prefocusing micro-optic makes optimal use of the elliptical shape of the capillary by almost eliminating aberrations. A small cross section of the prefocused beam allows a tiny fraction of the capillary surface...
متن کاملUltrahigh energy resolution focusing monochromator for inelastic x-ray scattering spectrometer.
A further development of a focusing monochromator concept for X-ray energy resolution of 0.1 meV and below is presented. Theoretical analysis of several optical layouts based on this concept was supported by numerical simulations performed in the "Synchrotron Radiation Workshop" software package using the physical-optics approach and careful modeling of partially-coherent synchrotron (undulator...
متن کاملA Review of the Applications of Synchrotron Radiation in Archaeological Sciences
The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...
متن کاملHigh-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam
A pre-focused X-ray beam at 12 keV and 9 keV has been used to illuminate a single-bounce capillary in order to generate a high-flux X-ray microbeam. The BioCAT undulator X-ray beamline 18ID at the Advanced Photon Source was used to generate the pre-focused beam containing 1.2 x 10(13) photons s(-1) using a sagittal-focusing double-crystal monochromator and a bimorph mirror. The capillary entran...
متن کاملMonocapillary Optics Developments and Applications
Hollow glass tubes are in use at Cornell High Energy Synchrotron Source (CHESS) as X-ray optics in the 4 to 25 keV range to take large diameter, fairly parallel X-ray beams and compress them into smaller diameter, more divergent beams for various kinds of X-ray applications. The optics come in two forms: 1) multibounce condensing capillaries for making submicron diameter beams and 2) one-bounce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of synchrotron radiation
دوره 13 Pt 1 شماره
صفحات -
تاریخ انتشار 2006