A correlation of the logarithmic values of the in vitro dissolution rate, G, and the apparent solubility, S, was evaluated in phosphate and ammonium acetate buffer at an initial pH of 7. The dissolution rates were determined with a newly designed and build miniaturized rotating disk equipment, as well as with a traditional rotating disk apparatus. The two apparatuses gave the same correlation pattern of logG and logS. Thirteen diverse drug substances from all of the classes in the Biopharmaceutics Classification System (BCS) were used for the correlation in the phosphate buffer system, with the results from the miniaturized apparatus only. A coefficient of determination, R2, of 0.982 was found if bases formulated as hydrochloride salts were excluded in the correlation. The miniaturized equipment is used for rapid screening of the dissolution rate, approximately 10 min for one run, and consumes small amounts of substance (about 5 mg) and dissolution media. All quantifications were performed by using reversed phase high-performance liquid chromatography (RPHPLC) with a diode array detector (DAD), integrated with the miniaturized rotating disk equipment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Intrinsic Dissolution Rate Using Miniaturized Rotating and Stationary Disk Systems

The objective of this study was to assess the feasibility and reliability of using miniaturized disk dissolution apparatus for intrinsic dissolution rate (IDR) measurement in the early drug discovery process when bulk drug supply is very limited. The two apparatus, a miniaturized rotating disk system (mRDS) and a miniaturized stationary disk system (mSDS), were evaluated using chloramphenicol a...

متن کامل

Convective Heat Transfer from a Heated Rotating Disk at Arbitrary Inclination Angle in Laminar Flow

In this paper, experimental data and numerical results of heat transfer from a heated rotating disk in still air are presented over a large range of inclination angles and a dimensionless correlation is developed for forced, natural and mixed convection. The measured Nusselt number over the rotating disk is compared with the numerical results. The goal of the present research is to develop a se...

متن کامل

Vibration Analysis of Rotating Shaft with Loose Disk

In this paper energy method is used to calculate rotor response with loose rotating disk on it. System equation of motion is obtained based on energy method and Lagrange equation. Mathematical modeling of loose disk in a rotor bearing system has resulted in terms similar to unbalance and gyroscopic effect in the system equation of motion. The effect of loose disk axial position and orthotropic ...

متن کامل

Magneto-Thermo-Elastic Stresses and Perturbation of Magnetic Field Vector in a Thin Functionally Graded Rotating Disk

In this paper, a semi-analytical solution for magneto-thermo-elastic problem in an axisymmetric functionally graded (FG) hollow rotating disk with constant thickness placed in uniform magnetic and thermal fields with heat convection from disk’s surfaces is presented. Solution for stresses and perturbation of magnetic field vector in a thin FG rotating disk is determined using infinitesimal theo...

متن کامل

Experimental and Computational Study on Hydrodynamic of a Downscaled Mini Vessel USP Dissolution Test Apparatus II

Although not listed on the United States Pharmacopeia (USP), like standard USP 2, small volume USP 2 dissolution apparatus has gained a great deal of attention, especially for cases where small amount of drug product is available for testing in research and design step or evaluations are to be made on a tablet containing trace amounts of the active pharmaceutical ingredient. In this work, first...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Drug discoveries & therapeutics

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 2009