Fixation of subtrochanteric fractures

نویسنده

  • Elsayed Ibraheem Elsayed Massoud
چکیده

The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult for the treating surgeon. The preferred type of device is a matter of debate. Increased understanding of mechanical characteristics of the dynamic hip screw (DHS) has reduced the incidence of complications. Our hypothesis is based on the technical optimization of the DHS application. We prospectively studied 37 patients with subtrochanteric fractures with a mean age of 42.9 years. We utilized a two-stage protocol: initially, conversion of the comminuted fractures into two part fractures; then application of the implant with a technique that allowed dynamization of the DHS. Clinical and radiographic data were used to assess the outcome at 12 months. Fracture healing was obtained for all cases in a mean time of 11.64 weeks. One patient had 1.5 cm shortening of the injured limb. No implant failure was reported. All patients resumed pre-injury activities of daily living. It was concluded that the patients who were treated with the technical optimization of the DHS application achieved a close-to-normal anatomy following surgery and maintained this state throughout the follow-up period.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تکنیک صفحه‌گذاری بیولوژیک در شکستگی‌های چند قطعه‌ای ساب‌تروکانتریک استخوان ران

Background: Comminuted subtrochanteric fractures have been a challenge for orthopedic surgeons in terms of appropriate reduction and stable fixation. Numerous methods have been used for the fixation of comminuted subtrochanteric fractures among which some are accompanied with technical difficulties and complications of their own. Regarding the results of previous studies, we decided to evaluate...

متن کامل

Management of Subtrochanteric Fracture Femur by Proximal Femoral Nail

Background: Subtrochanteric fractures of the femur remain some of the most challenging fractures faced by orthopaedic surgeons. Most of the fractures in the elderly results from trivial fall from standing or while walking, whereas in the younger age group it is mainly due to road traffic accidents. Closed management of these subtrochanteric fractures poses difficulties in obtaining and maintain...

متن کامل

Experience with the Zickel device.

SUBTROCHANTERIC fractures of the femur are difficult to treat successfully. Fractures in this region show typical displacement. The strong gluteal muscles abduct the proximal fragment, whereas the adductors inserted below the fracture site adduct the distal fragment-see Figure 1. Biomechanical analysis of stress in the femur shows a high concentration of stress in the subtrochanteric region. Al...

متن کامل

Reconstruction plate fixation of subtrochanteric femoral fractures in children.

Pediatric subtrochanteric femoral fractures are rare and have received limited attention in the literature Treatment is controversial. Different treatment options are used: skin traction, 90/90 skeletal traction, spica casting, cast bracing, internal fixation and external fixation. The aim of this study is to present our results with internal fixation of subtrochanteric femoral fractures in chi...

متن کامل

Intramedullary versus extramedullary fixation in the management of subtrochanteric femur fractures: a meta-analysis

BACKGROUND Intramedullary and extramedullary fixation methods are used in the management of subtrochanteric femur fractures. However, whether intramedullary or extramedullary fixation is the primary treatment for subtrochanteric femur fractures in adults remains debatable. LEVEL OF EVIDENCE Meta-analyses of prospective studies, level I. MATERIALS AND METHODS The Cochrane library, Embase, Go...

متن کامل

Does screw configuration affect subtrochanteric fracture after femoral neck fixation?

A subtrochanteric femur fracture after cannulated screw fixation of a femoral neck fracture is a devastating complication. We hypothesized that an apex-distal screw orientation would tolerate higher loads to subtrochanteric fracture. Human cadaveric femora were instrumented with three cannulated screws in either an apex-distal or an apex-proximal configuration. Specimens were loaded along the m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Strategies in Trauma and Limb Reconstruction

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2009