Semiautomated quantification of hepatitis B virus DNA in a routine diagnostic laboratory.

نویسندگان

  • H H Kessler
  • E Stelzl
  • E Daghofer
  • B I Santner
  • E Marth
  • H Lackner
  • R E Stauber
چکیده

The Cobas Amplicor HBV Monitor test for quantitative determination of hepatitis B virus (HBV) DNA in serum has recently been introduced. To evaluate the performance of this assay in a routine diagnostic laboratory, reproducibility of results was determined with the First European Union Concerted Action HBV Proficiency Panel and the Accurun 325 HBV DNA Positive Control, Series 300. Results for 270 routine serum samples were additionally evaluated. To avoid the retesting of a large number of samples due to titers exceeding the upper limit for the linear range of the assay, sera of patients with chronic hepatitis B (CHB) were diluted prior to the assay to 10(-4) in normal human plasma, which is included in the assay. The mean coefficient of variation was 22.9% for all input HBV DNAs. Of 270 routine serum samples, 182 (150 sera from transplant donors and 32 sera from patients who had recovered from CHB) tested negative. Eighty-six sera were found to be HBV DNA positive; in six sera, HBV DNA levels were found to exceed the upper limit for the linear range of the assay and had to be retested. In the remaining two sera, inhibition occurred. The semiautomated Cobas Amplicor HBV Monitor test showed sufficient reproducibility and helped in avoiding human error. The relatively narrow linear range of detection is a limitation of the new assay.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

کلونینگ ژن کدکننده آنتی‌ژن سطحی ویروس هپاتیت B در اشرشیاکولی

    Background & Aim: Hepatitis B virus(HBV) infection is endemic worldwide. It is estimated every year more than 350 million people become infected with HBV(new cases) worldwide. Unfortunately, there are no satisfactory drugs to cure HBV and related diseases and the only way to control it is through vaccination. Measurements of HBV DNA levels are routinely used to identify infectious chronic c...

متن کامل

Frequency of Torque Teno Mini Virus in Hepatitis B and C Patients and Healthy Blood Donors in Isfahan, Iran

Background: Recently, some new viruses have been identified for their association with hepatitis which Torque Teno Mini Virus being among them. The aim of this study was to determine the frequency of Torque Teno Mini Virus in healthy individuals and hepatitis B and C patients in Isfahan, Iran. Materials and Methods: One hundred serum samples of healthy individuals from Isfahan Blood Transfusi...

متن کامل

Quality Control Planning of a Hepatitis B Viral Load Laboratory-Developed Assay

  Background and Objectives: HBV DNA monitoring is important in management of chronic viral hepatitis B infection. HBV DNA measurements are carried out over period of months to years. So the analytical system must be stable and reproducible. The aim of this study was to determine the performance characteristics and to plan a statistical quality control system of a laboratory-developed real-tim...

متن کامل

Expression of Hepatitis B Virus Core Antigen in Native and Fusion Forms in E. coli

DNA coding for the core antigen from hepatitis B Virus (HBcAg) was amplified, cloned and propagated in E. coli. The core protein was expressed in E. coli and the product was readily detected by Western blot. This protein can be used as a diagnostic material in serum screening tests. To increase the level of expression of this antigen in bacteria, two plasmids were constructed in which the gene ...

متن کامل

Frequency of YMDD mutations in patients with chronic hepatitis B untreated with antiviral medicines

 Abstract Background: Investigators were suspicious of tyrosine-methionine-aspartate-aspartate (YMDD) mutations occurred only in patients who were treated by lamivudine. However, YMDD mutations of hepatitis B virus gene (HBV DNA) in patients with chronic hepatitis B (CHB) untreated with antiviral medicines was reported in some studies. The aim of this study was to evaluate YMDD mutations in Ira...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical and diagnostic laboratory immunology

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2000