DLA based compressed sensing for high resolution MR microscopy of neuronal tissue.

نویسندگان

  • Khieu-Van Nguyen
  • Jing-Rebecca Li
  • Guillaume Radecki
  • Luisa Ciobanu
چکیده

In this work we present the implementation of compressed sensing (CS) on a high field preclinical scanner (17.2 T) using an undersampling trajectory based on the diffusion limited aggregation (DLA) random growth model. When applied to a library of images this approach performs better than the traditional undersampling based on the polynomial probability density function. In addition, we show that the method is applicable to imaging live neuronal tissues, allowing significantly shorter acquisition times while maintaining the image quality necessary for identifying the majority of neurons via an automatic cell segmentation algorithm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative DLA-based Compressed Sensing for MEMRI Acquisitions

Purpose: High resolution Manganese Enhanced Magnetic Resonance Imaging (MEMRI) has great potential for functional imaging of live neuronal tissue at single neuron scale. However, reaching high resolutions often requires long acquisition times which can lead to reduced image quality due to sample deterioration and hardware instability. Compressed Sensing (CS) techniques offer the opportunity to ...

متن کامل

Increasing Depth Resolution of Electron Microscopy of Neural Circuits using Sparse Tomographic Reconstruction

Future progress in neuroscience hinges on reconstruction of neuronal circuits to the level of individual synapses. Because of the specifics of neuronal architecture, imaging must be done with very high resolution and throughput. While Electron Microscopy (EM) achieves the required resolution in the transverse directions, its depth resolution is a severe limitation. Computed tomography (CT) may ...

متن کامل

Accelerated phase contrast measurements of fetal blood flow using compressed sensing

Background Phase contrast (PC) MR is routinely used to quantify blood flow in postnatal subjects and through the use of metric optimized gating (MOG) has been employed in studies of fetal blood flow in both normal pregnancies and fetal congenital heart disease [1-3]. Still, the scan time required for high resolution fetal PCMR remains a practical limitation. Recently, compressed sensing (CS) ha...

متن کامل

Super-resolution using Sparse Representations over Learned Dictionaries: Reconstruction of Brain Structure using Electron Microscopy

A central problem in neuroscience is reconstructing neuronal circuits on the synapse level. Due to a wide range of scales in brain architecture such reconstruction requires imaging that is both high-resolution and high-throughput. Existing electron microscopy (EM) techniques possess required resolution in the lateral plane and either high-throughput or high depth resolution but not both. Here, ...

متن کامل

Joint reconstruction of simultaneously acquired MR-PET data with multi sensor compressed sensing based on a joint sparsity constraint

Bernard & Irene Schwartz Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA State-of-the-art MR-PET scanners allow simultaneous data acquisition. However, image reconstruction is performed separately and results are only combined at the visualization stage. PET images are reconstructed using a variant of EM and MR data are reconstructed using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 259  شماره 

صفحات  -

تاریخ انتشار 2015