Baseline serum globulin as a predictor of the recurrence of lone atrial fibrillation after radiofrequency catheter ablation

نویسندگان

  • Qing Zhou
  • Hailong Cao
  • Zhenjun Xu
  • Rongfang Lan
  • Xin Chen
  • Dongjin Wang
  • Wei Xu
چکیده

OBJECTIVE Inflammation and autoimmune responses play an important role in recurrence of atrial fibrillation (AF). Serum globulin levels are a commonly used clinical index that represents inflammation and autoimmune response. This study aimed to determine the relationship between baseline serum globulin levels and the risk of recurrence after ablation in lone AF patients. METHODS We enrolled 348 lone AF patients undergoing radiofrequency catheter ablation for the first time for whom complete follow-up data were available. Pre-ablation peripheral venous blood samples were obtained for measurement of serum globulin levels. RESULTS During the follow-up period of 22 months (range, 6-62), AF recurred in 129 patients (37.1%). Recurrence was associated with a low level of pre-ablation serum globulins. Multiple Cox proportional hazard regression analysis showed that persistent AF, AF duration, left atrial diameter, no amiodarone after ablation, and the serum globulin level in particular were independent predictors of AF recurrence. According to receiver operating characteristic curve analysis, the best diagnostic cut-off serum globulin level was 25.4 g/L, which showed 74.4% sensitivity, 71.3% specificity, and 73.3% accuracy. CONCLUSION The baseline low serum globulin level is associated with AF recurrence after first-time ablation in lone AF patients. Therefore, it may be used as a predictor of AF recurrence in these patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The serum matrix metalloproteinase-9 level is an independent predictor of recurrence after ablation of persistent atrial fibrillation

OBJECTIVES This study investigated whether the serum matrix metalloproteinase-9 level is an independent predictor of recurrence after catheter ablation for persistent atrial fibrillation. METHODS Fifty-eight consecutive patients with persistent atrial fibrillation were enrolled and underwent catheter ablation. The serum matrix metalloproteinase-9 level was detected before ablation and its rel...

متن کامل

Left atrial emptying fraction predicts recurrence of atrial fibrillation after radiofrequency catheter ablation

BACKGROUND Compared with left atrial (LA) dimension, LA emptying fraction (LAEF) has received less emphasis as a predictor of atrial fibrillation (AF) recurrence after radiofrequency catheter ablation (RFCA). In addition, patients experiencing post-RFCA AF recurrence may respond to previously ineffective antiarrhythmic drugs (AADs). Classifying these patients into a third RFCA outcome category ...

متن کامل

Effect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin

  Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation.   A total of 100 patients with AF w...

متن کامل

Effect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin

  Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation.   A total of 100 patients with AF w...

متن کامل

Impact of metabolic syndrome on left atrial electroanatomical remodeling and outcomes after radiofrequency ablation of nonvalvular atrial fibrillation.

BACKGROUND Recent studies reported worse outcomes after atrial fibrillation (AF) ablation in patients with metabolic syndrome (MetS). However, mechanisms of AF recurrence in MetS remain unclear. METHOD AND RESULTS We performed pulmonary vein isolation and voltage mapping in 236 patients with AF (age 61±9.6 years; persistent AF 64%; MetS 54%). Left atrial (LA) low voltage areas were semiquanti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017