This thesis focuses on the analysis of the cardiac electrical and kinematic function for heart failure patients. An expected outcome is a set of computational tools that may help a clinician in understanding, diagnosing and treating patients su ering from cardiac motion asynchrony, a speci c aspect of heart failure. Understanding the inverse electro-kinematic coupling relationship is the main task of this study. With this knowledge, the widely available cardiac image sequences acquired non-invasively at clinics could be used to estimate the cardiac electrophysiology (EP) without having to perform the invasive cardiac EP mapping procedures. To this end, we use real clinical cardiac sequence and a cardiac electromechanical model to create controlled synthetic sequence so as to produce a training set in an attempt to learn the cardiac electro-kinematic relationship. Creating patient-speci c database of synthetic sequences allows us to study this relationship using a machine learning approach. A rst contribution of this work is a non-linear registration method applied and evaluated on cardiac sequences to estimate the cardiac motion. Second, a new approach in the generation of the synthetic but virtually realistic cardiac sequence which combines a biophysical model and clinical images is developed. Finally, we present the cardiac electrophysiological activation time estimation from medical images using a patient-speci c database of synthetic image sequences.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy window setting for optimum Tl-201 cardiac imaging [Persian]

  Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...

متن کامل

Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis

In this study, a method for non-invasive estimation of stress on the heart wall in  the diastole phase is presented using ultrasound echocardiography and tissue Doppler  imaging. The aim of this study was to evaluate the stress on the heart wall as a  pre-diagnosis  to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...

متن کامل

A Multimodal Discourse Analysis of Some Visual Images in the Political Rally Discourse of 2011 Electioneering Campaigns in Southwestern Nigeria

This paper presented a multimodal discourse analysis of some visual images in the political rally discourse of 2011 electioneering campaigns in Southwestern Nigeria. The data comprised purposively selected political visual artefacts from political rallies across the six Southwestern States in Nigeria (Osun, Oyo, Ondo, Ekiti, Ogun, and Lagos). The data were analyzed using Halliday’s (1985) syste...

متن کامل

Multimodal medical image fusion based on Yager’s intuitionistic fuzzy sets

The objective of image fusion for medical images is to combine multiple images obtained from various sources into a single image suitable for better diagnosis. Most of the state-of-the-art image fusing technique is based on nonfuzzy sets, and the fused image so obtained lags with complementary information. Intuitionistic fuzzy sets (IFS) are determined to be more suitable for civilian, and medi...

متن کامل

Prediction of long-term cardiac events by 123I-MIBG imaging after acute myocardial infarction and reperfusion therapy

Objective(s): In heart failure, the heart-to-mediastinum (H/M) ratio of the delayed image and washout rate (WR) are well-known as a powerful cardiac event predictors. H/M ratio quantifies the accumulation rate of MIBG in the myocardium and WR quantifies reduction of meta-iodobenzylguanidine (MIBG) accumulation in the heart from the early planar image to the delayed pla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017