Suitability of radiochromic medium for real-time optical measurements of ionizing radiation dose.

نویسندگان

  • Alexandra Rink
  • I Alex Vitkin
  • David A Jaffray
چکیده

A system, consisting of a novel optical fiber-based readout configuration and model-based method, has been developed to test suitability of a certain radiochromic medium for real-time measurements of ionizing radiation dose. Using this system with the radiochromic film allowed dose measurements to be performed during, and immediately after, exposure. The rates of change in OD before, during, and after exposure differ, and the change in OD during exposure was found to be proportional to applied dose in the tested range of 0-4 Gy. Estimating applied dose within an average error of less than 5% did not require a waiting time of 24-48 h as generally recommended with this radiochromic film. The errors can be further reduced by performing a calibration for each individual dosimeter setup instead of relying on batch calibration. Measurements of change in OD were found to be independent of dose-rate in the 95-570 cGy/min range for applied dose of 1 Gy or less. Some error was introduced due to dose-rate variation for doses of 2 Gy and above. The major limiting factor in utilizing this radiation sensitive medium for real-time in vivo dosimetry is the strong dependence on temperature in the clinically relevant range of 20-38 degrees C.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium.

A new radiochromic film, GafChromic EBT, was investigated for use in a real-time radiation dosimetry system. It was found to be approximately eight times more sensitive to ionizing radiation dose, exhibited less postexposure development and achieved stable readout faster than one of its predecessors, GafChromic MD-55. A clear distinction in change in optical density between exposure and postexp...

متن کامل

Investigation of the Effect of Electron Beam Different Doses on Optical Dissipation in Fiber Optic

Measurement of ionizing radiation in various fields, such as environmental safety, industrial detection processes, radiation protection and medical is very important. Radiation dosimetry plays an important role in determining the amount of energy absorbed and the effects of radiation. Recent optical fiber sensors have been shown to be radiation dosimeters. Our goal here is to investigate the ef...

متن کامل

Dosimetric comparison between XR-RV3 and EBT2 radiochromic film in megavoltage photon beams

Background:  Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

متن کامل

Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium.

The effects of temperature on real time changes in optical density (DeltaOD) of GAFCHROMIC EBT film were investigated. The spectral peak of maximum change in absorbance (lambdamax) was shown to downshift linearly when the temperature of the film was increased from 22 to 38 degrees C. The DeltaOD values were also shown to decrease linearly with temperature, and this decrease could not be attribu...

متن کامل

Linearity response characterization of Polystyrene/ Graphene oxide nanocomposite as real-time dosimeter for therapeutic purposes

Introduction: In recent years, one of the emerging two dimensional (2D) carbon based nano- materials namely Graphene Oxide has been incorporated into polymeric matrices to enhance the electrical properties of the composites. The electrical conductivity of Graphene Oxide is excellently used in fabricating polymer-based sensors, energy-related systems, biotechnology, anti-statics...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 2005