A method for PID controller tuning based on process models for series cascaded control systems using anti-reset windup technique is proposed in this paper. Closed loop response is obtained using auto tuning of PID controller. This method can be applied to any closed loop stable processes. Closed loop responses of series cascade control loops tuned by the proposed anti-reset windup technique method are compared with the existing cascade control system. Simulation results on nonlinear stable continuous stirred tank reactors is presented to show the efficiency of the proposed controller using anti-reset windup technique.
منابع مشابه
Control of a Fluidized Bed Polyethylene Reactor
In present paper, dynamic behavior and control of a fluidized bed reactor for polyethylene production has been considered. A double active sites model for Ziegler-Natta catalysts is used for simulation of polymerization reaction. Hydrodynamic behavior of the bed is modeled using a two phase model including bubble and emulsion phases in which bubble phase has plug flow pattern with different...
متن کاملA Comparison of Different Control Design Methods for the Linearized CSTR Temperature Model
Continuous Stirred Tank Reactor (CSTR) has particular importance in chemical industry. CSTR has usually a nonlinear behavior which makes it difficult to control. The reactor has two parameters: the concentration and temperature of mixture both of which are uncertain. This case of CSTR has large disturbance in domain. In order for disturbance rejection, a controller has to be designed. In this p...
متن کاملRobust Anti-Windup Control Design for PID Controllers–Theory and Experimental Verification
This paper addresses an approximation-based anti-windup (AW) control strategy for suppressing the windup effect caused by actuator saturation nonlinearity in proportional–integral–derivative (PID) controlled systems. The effect of actuator constraint is firstly regarded as a disturbance imported to the PID controller. The external disturbance can then be modeled by a linear differential equatio...
متن کاملRobust Anti-Windup Control Design for PID Controllers–Theory and Experimental Verification
This paper addresses an approximation-based anti-windup (AW) control strategy for suppressing the windup effect caused by actuator saturation nonlinearity in proportional–integral–derivative (PID) controlled systems. The effect of actuator constraint is firstly regarded as a disturbance imported to the PID controller. The external disturbance can then be modeled by a linear differential equatio...
متن کاملA Novel Method to Increase the Power Capacity of Transmission Lines Using Transformerless Static Synchronous Series Compensator
In this paper a transformerless Static Synchronous Series Compensator (SSSC) to increase the power capacity of a 230 kV transmission line is proposed. In order to eliminate the transformer, a 15-level cascade H Bridge (CHB) inverter is employed within the proposed compensator structure to inject reactive power to the transmission line. The theory of instantaneous p-q power using in the compensa...