The ATLAS liquid argon hadronic end-cap calorimeter: construction and selected beam test results

نویسنده

  • T. Barillari
چکیده

ATLAS has chosen for its Hadronic End-Cap Calorimeter (HEC) the copper-liquid argon sampling technique with flat plate geometry and GaAs pre-amplifiers in the argon. The contruction of the calorimeter is now approaching completion. Results of production quality checks are reported and their anticipated impact on calorimeter performance discussed. Selected results, such as linearity, electron and pion energy resolution, uniformity of energy response, obtained in beam tests both of the Hadronic End-Cap Calorimeter by itself, and in the ATLAS configuration where the HEC is in combination with the Electromagnetic End-Cap Calorimeter (EMEC) are described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid Argon Pollution Tests of the ATLAS Detector Materials at IBR-2 Reactor in Dubna

A cold test facility has been in operation since October 1998 at the IBR-2 reactor of JINR, Dubna. During four measurement campaigns, various samples of the ATLAS forward (FCAL) and hadronic end cap (HEC) calorimeter materials have been exposed to a fast neutron (En 100 keV) uence of about 10 16 n cm . The samples were immersed in a liquid argon cryostat, and an -cell has been used as purity mo...

متن کامل

Commissioning and Performance of the ATLAS Liquid Argon Calorimeters

The ATLAS liquid argon (LAr) calorimeter system consists of an electromagnetic barrel calorimeter and two end-caps with electromagnetic, hadronic and forward calorimeters. The construction of the full calorimeter system is completed since mid-2004. The detector has been operated with LAr at nominal high voltage and fully equipped with readout electronics. Online software, monitoring tools and o...

متن کامل

Charged Pion Energy Reconstruction in the ATLAS Barrel Calorimeter

The intrinsic performance of the ATLAS barrel and extended barrel calorimeters for the measurement of charged pions is presented. Pion energy scans (E = 20, 50, 200, 400 and 1000 GeV) at two pseudo-rapidity points (η = 0.3 and 1.3) and pseudorapidity scans (−0.2 < η < 1.8) with pions of constant transverse energy (ET = 20 and 50 GeV) are analysed. A simple approach, that accounts in first order...

متن کامل

Lifetime Test for Optical Transmitters in the ATLAS Liquid Argon Calorimeter Readout System

Accelerated lifetime test has been carried out for 147 days on the custom-made optical transmitters used in the ATLAS Liquid Argon Calorimeter front-end electronics readout system. The lifetime of these optical transmitters is estimated to be greater than 200 years and exceeds the design goal for the LHC. The random failure rate has been estimated at 9.6×10 per hour at 90% confidence level.

متن کامل

Quality Control of Optical Transmitters for the ATLAS Liquid Argon Calorimeter

A quality control test is performed on nearly 2000 custom optical transmitters for use in the Liquid Argon Calorimeter of the ATLAS detector. More than 90% of these optical transmitters passed the test and have been installed in the calorimeter readout system. The acceptance criteria, measurement procedure, and results of the quality control test are presented in this note.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004