In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.
نویسندگان
چکیده
The delivery of gaseous microemboli (GME) by the cardiopulmonary bypass circuit should be minimized whenever possible. Innovations in components, such as the integration of arterial line filter (ALF) and ALFs with reduced priming volumes, have provided clinicians with circuit design options. However, before adopting these components clinically, their GME handling ability should be assessed. This study aims to compare the GME handling ability of different oxygenator/ALF combinations with our currently utilized combination. Five commercially available oxygenator/ALF combinations were evaluated in vitro: Terumo Capiox SX25RX and Dideco D734 (SX/D734),Terumo Capiox RX25R and AF125 (RX/AF125), Terumo FX25R (FX), Sorin Synthesis with 102 microm reservoir filter (SYN102), and Sorin Synthesis with 40 microm reservoir filter (SYN40). GME handling was studied by introducing air into the venous return at 100 mL/min for 60 seconds under two flow/ pressure combinations: 3.5 L/min, 150 mmHg and 5 L/min, 200 mmHg. Emboli were measured at three positions in the circuit using the Emboli Detection and Classification (EDAC) Quantifier and analyzed with the General Linear Model. All circuits significantly reduced GME. The SX/D734 and SYN40 circuits were most efficient in GME removal whilst the SYN102 handled embolic load (count and volume) least efficiently (p < .001). A greater number of emboli <70 microm were observed for the SYN102, FX and RX/AF125 circuits (p < .001). An increase in embolic load occurred with higher flow/pressure in all circuits (p < .001). The venous reservoir significantly influences embolic load delivered to the oxygenator (p < .001). The majority of introduced venous air was removed; however, significant variation existed in the ability of the different circuits to handle GME. Venous reservoir design influenced the overall GME handling ability. GME removal was less efficient at higher flow and pressure, and for smaller sized emboli. The clinical significance of reducing GME requires further investigation.
منابع مشابه
Blood temperature management and gaseous microemboli creation: an in-vitro analysis.
Gaseous microemboli have been associated with post operative neurological deficits in patients undergoing cardiopulmonary bypass. Creating an optimal perfusion system that minimizes microemboli production and has enhanced abilities to sequester entrained air during the bypass procedure has been an important focus. This study examines the air-handling capabilities of a cardiopulmonary bypass cir...
متن کاملGaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study.
Miniaturizing cardiopulmonary bypass (CPB) circuits to reduce hemodilution and allogenic blood product administration is common in cardiac surgery. One major concern associated with smaller CPB circuits is a possible increase in gaseous microemboli (GME) sent to the cerebral vasculature, which is exacerbated by vacuum-assisted venous drainage (VAVD). The use of VAVD has increased with smaller v...
متن کاملHow effective are cardiopulmonary bypass circuits at removing gaseous microemboli?
An association has been demonstrated between intravascular microemboli and organ injury during cardiopulmonary bypass (CPB). Air may be inadvertently introduced into the venous line during CPB resulting in the formation of gaseous microemboli (GME). We studied the ability of CPB circuits, from five different manufacturers, to remove GME originating from the introduction of air into the venous l...
متن کاملComparison of gaseous microemboli counts in arterial, simultaneous and venous heat exchange with a hollow fiber membrane oxygenator.
Potential sources of gaseous microemboli during cardiopulmonary bypass are varied. However, it is known that membrane oxygenators generate fewer gaseous microemboli than bubble oxygenators and that bubblers cannot utilize arterial heat exchange without generating significant gaseous microemboli during rewarming. A membrane oxygenator utilizing simultaneous gas and heat exchange raises the con...
متن کاملPreventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation.
The detection and prevention of gaseous microemboli (GMEs) during cardiopulmonary bypass has generated considerable interest within the cardiac surgical community. There have been several landmark papers that have used transcranial Doppler devices during cardiopulmonary bypass to detect gaseous microemboli activity in the patients' middle cerebral artery during perfusionist interventions. To de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of extra-corporeal technology
دوره 43 3 شماره
صفحات -