Signal normalization reduces systematic measurement differences between spectral-domain optical coherence tomography devices.
نویسندگان
چکیده
PURPOSE To test the effect of a novel signal normalization method for reducing systematic optical coherence tomography (OCT) measurement differences among multiple spectral-domain (SD) OCT devices. METHODS A total of 109 eyes from 59 subjects were scanned with two SD-OCT devices (Cirrus and RTVue) at the same visit. Optical coherence tomography image data were normalized to match their signal characteristics between the devices. To compensate signal strength differences, custom high dynamic range (HDR) processing was also applied only to images with substantially lower signal strength. Global mean peripapillary retinal nerve fiber layer (RNFL) thicknesses were then measured automatically from all images using custom segmentation software and were compared to the original device outputs. Structural equation models were used to analyze the absolute RNFL thickness difference between original device outputs and our software outputs after signal normalization. RESULTS The device-measured RNFL thickness showed a statistically significant difference between the two devices (mean absolute difference 10.58 μm, P < 0.05), while there was no significant difference after normalization on eyes with 62.4-μm or thicker RNFL (mean absolute difference 2.95 μm, P < 0.05). CONCLUSIONS The signal normalization method successfully reduces the systematic difference in RNFL thickness measurements between two SD-OCT devices. Enabling direct comparison of RNFL thickness obtained from multiple devices would broaden the use of OCT technology in both clinical and research applications.
منابع مشابه
Individual A-scan signal normalization between two spectral domain optical coherence tomography devices.
PURPOSE We developed a method to normalize optical coherence tomography (OCT) signal profiles from two spectral-domain (SD) OCT devices so that the comparability between devices increases. METHODS We scanned 21 eyes from 14 healthy and 7 glaucoma subjects with two SD-OCT devices on the same day, with equivalent cube scan patterns centered on the fovea (Cirrus HD-OCT and RTVue). Foveola positi...
متن کاملSignal Normalization Reduces Image Appearance Disparity Among Multiple Optical Coherence Tomography Devices
PURPOSE To assess the effect of the previously reported optical coherence tomography (OCT) signal normalization method on reducing the discrepancies in image appearance among spectral-domain OCT (SD-OCT) devices. METHODS Healthy eyes and eyes with various retinal pathologies were scanned at the macular region using similar volumetric scan patterns with at least two out of three SD-OCT devices...
متن کاملبررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک
Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملComparing Macular Thickness Measurements in Patients with Diabetic Macular Edema with the Optos Spectral OCT/SLO and Heidelberg Spectralis HRA + OCT
The aim of this study was to compare measurements of macular thickness, obtained from patients with diabetic macular edema, using two spectral-domain optical coherence tomography (SD-OCT) devices. These were the Spectralis Heidelberg Retina Angiograph + Optical Coherence Tomography (HRA + OCT) (Heidelberg Engineering), which is often considered the gold-standard for OCT measurement, and the Spe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 54 12 شماره
صفحات -
تاریخ انتشار 2013