Fully Automated Self-calibrating Hybrid Flow Analyzer for Gaseous Formaldehyde

نویسندگان

  • In-Yong Eom
  • Qingyang Li
  • Jianzhong Li
  • Purnendu K. Dasgupta
چکیده

We report fully automated self-calibrating formaldehyde analyzers relying on a hybrid flow format and include operational scheme and design details. Long-term operation is made possible with the use of syringe pumps. Four identical analyzers were built and showed low LODs of 120 pptv or better (S/N =3) and good linearity over 0-50 ppbv HCHO concentration range (r > 0.9960). The analyzer can resume normal operation after short-term power failure with at most two cycles of data loss following restart. Good agreement between analyzers was observed for either indoor or outdoor

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Enzymatic Method for Pectin Methyl Esters Determination

Pectin is a natural polysaccharide used in food and pharma industries. Pectin degree of methylation is an important parameter having significant influence on pectin applications. A rapid, fully automated, kinetic flow method for determination of pectin methyl esters has been developed. The method is based on a lab-made analyzer using the reverse flow-injection/stopped flow principle. Methanol i...

متن کامل

حذف فتوکاتالیستی فرمالدئید از هوا با استفاده از نانوکامپوزیت اکسید تیتانیوم- اکسید گرافن احیاء شده

Background and Objective: Formaldehyde is a toxic volatile organic compound, which its removal from polluted air is essential. One of the techniques available for removing such compounds is photocatalytic degradation. The aim of this study was to investigate the photocatalytic degradation of gaseous formaldehyde on TiO2 nanoparticles coated on reduced graphene oxide Materials and Methods...

متن کامل

A multiple processing hybrid flow system for analysis of formaldehyde contamination in food.

This work proposes a flow system suitable for the rapid screening of formaldehyde contaminated in food. The system is based on the concept of a flow analyzer with a Hantzsch reaction. An operating procedure was developed for multiple tasking and high sample throughput. This resulted in a significant sample throughput of 51 samples h(-1). Under the optimized conditions, linear calibration from 1...

متن کامل

Automated portable analyzer for lead(II) based on sequential flow injection and nanostructured electrochemical sensors.

A fully automated portable analyzer for toxic metal ion detection based on a combination of a nanostructured electrochemical sensor and a sequential flow injection system has been developed in this work. The sensor was fabricated from a carbon paste electrode modified with acetamide phosphonic acid self-assembled monolayer on mesoporous silica (Ac-Phos SAMMS) which was embedded in a very small ...

متن کامل

Self-calibrating binary polarization analyzer.

We report a self-calibrating polarization analyzer fabricated with binary magneto-optic polarization rotators. The device automatically overcomes wavelength and temperature dependent inaccuracies and has impressive state of polarization and degree of polarization accuracies of 0.3 degrees and +/-0.5%, respectively, from 1460 to 1580 nm.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007