The most attractive feature of SDA is its operation at a single temperature, which removes the need for instrumented temperature cycling as with PCR and the ligase chain reaction. Highly reproducible temperature profiles, over a large array of samples, can burden the accuracy and expense of an amplification technique. However, the expense of a temperature cycler is offset somewhat by the cost of additional enzymes used in isothermal techniques. In comparisons with isothermal, transcription-based techniques, SDA requires fewer enzymes and has a simpler mechanism. SDA may also be more robust than transcription-based processes because it is not susceptible to contaminating ribonuclease activity. This is generally more of a concern when using clinical samples. The most significant disadvantage of SDA is its inability to efficiently amplify long target sequences. Until this short-coming is eliminated, SDA will be assigned to the diagnostic laboratory along with the ligase chain reaction. Currently, SDA cannot compete with PCR in research applications such as the isolation of gene sequences. The second disadvantage of SDA is that it operates at relatively low (nonstringent) temperatures, which produces considerable background reactions. Consequently, SDA reaction products cannot be analyzed routinely by ethidium-stained gel electrophoresis, as is used commonly with PCR, unless the target sample contains a large number of initial targets.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-molecule dilution and multiple displacement amplification for molecular haplotyping.

Separate haploid analysis is frequently required for heterozygous genotyping to resolve phase ambiguity or confirm allelic sequence. We demonstrate a technique of single-molecule dilution followed by multiple strand displacement amplification to haplotype polymorphic alleles. Dilution of DNA to haploid equivalency, or a single molecule, is a simple method for separating di-allelic DNA. Strand d...

متن کامل

Isothermal amplification system based on template-dependent extension.

A novel template-dependent extension based isothermal amplification (TEIA) system with high single-base discrimination capability is developed, where the interference caused by non-specific reaction in isothermal strand displacement amplification (SDA) technique is substantially avoided via using a functionalized template probe, showing potential value in the development and application of SDA ...

متن کامل

Invasive reaction assisted strand-displacement signal amplification for sensitive DNA detection.

A novel DNA detection assay was proposed by invasive reaction coupled with molecular beacon assisted strand-displacement signal amplification (IRASA). Target DNAs are firstly hybridized to two probes to initiate invasive reaction to produce amplified flaps. Then these flaps are further amplified by strand-displacement signal amplification. The detection limit was around 0.2 pM.

متن کامل

Development of small molecule biosensors by coupling the recognition of the bacterial allosteric transcription factor with isothermal strand displacement amplification.

Here, we demonstrate an easy-to-implement and general biosensing strategy by coupling the small-molecule recognition of the bacterial allosteric transcription factor (aTF) with isothermal strand displacement amplification (SDA) in vitro. Based on this strategy, we developed two biosensors for the detection of an antiseptic, p-hydroxybenzoic acid, and a disease marker, uric acid, using bacterial...

متن کامل

Simultaneous detection of mercury(II) and silver(I) ions with picomolar sensitivity.

We develop a new method for the simultaneous detection of Hg(2+) and Ag(+) by integrating bifunctional strand displacement amplification and multiplexed short linear quencher-fluorophore probes. This method exhibits excellent specificity and high picomolar sensitivity, which is improved by up to 4 orders of magnitude compared to the current approaches for metal ion assay.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • PCR methods and applications

دوره 3 1  شماره 

صفحات  -