Operative chest wall fixation with osteosynthesis plates.

نویسندگان

  • Christine Engel
  • James C Krieg
  • Steven M Madey
  • William B Long
  • Michael Bottlang
چکیده

Blunt chest wall trauma is a major cause of morbidity and mortality, especially in the presence of a flail chest where paradoxical inward movement of the flail segment in inspiration is found. Patients with a flail chest require aggressive pain control, pulmonary toilet, and often intubation and mechanical ventilation to establish an internal pneumatic stabilization of the flail segment. This may result in a prolonged ICU stay and pulmonary complications including pneumonia, septicemia and barotrauma. The high mortality rate of up to 10 –36% –12 is partly due to the high prevalence of associated life-threatening extra-thoracic injuries. However, one principle cause of death consists of pneumonia and sepsis with prolonged intubation. Several potential advantages of operative chest wall stabilizations have been reported. These include reduced duration of mechanical ventilation, shortened ICU stay and hospitalization, and decreased likelihood of clinically significant long-term respiratory dysfunction and skeletal deformity. Despite the advantages of operative chest wall fixation, little consensus on the fixation technique exists. This report describes three cases of flail chest injury managed by operative stabilization with plates and screws. The criteria for surgical intervention in this trauma center are traumatic loss of 30% of pleural cavity volume, inability to wean an awake patient from the ventilator, inability to control chest wall pain despite epidural catheter, major air leak or major bleeding, or unstable sternal fracture with overlap. In all three cases a standard posterolateral thoracotomy was performed. The serratus anterior was retracted anteriorly and the latissimus dorsi was divided. To reach more cranially a small portion of the trapezius and the rhomboids were transected in cases 2 and 3. The chest was always entered and hematoma was removed. Pelvic, mandibular and customized reconstruction plates were used, with bending stiffness ranging from 1,936 over 414 to 56 kN mm, respectively. In addition to documentation of the technique, this report describes the results obtained with three distinct osteosynthesis plates and provides a historic overview of alternative fixation means.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Surgical Fixation Using Bio-Absorbable Plates for Frail Chest in a Severe Osteoporotic Octogenarian.

We present a case of a severe osteoporotic octogenarian who sustained serious flail chest from a traffic accident. The 3rd-9th ribs of the right chest wall were fractured. Non-operative management was unsuccessful. We performed a surgical fixation using a bio-absorbable and bio-active mini-plating set. This plating set is unsintered hydroxyapatite (u-HA) particles/poly-L-lactide (PLLA) composit...

متن کامل

Surgical stabilization of flail chest injuries with MatrixRIB implants: a prospective observational study.

BACKGROUND Surgical stabilization of flail chest injury with generic osteosynthesis implants remains challenging. A novel implant system comprising anatomic rib plates and intramedullary splints may improve surgical stabilization of flail chest injuries. This observational study evaluated our early clinical experience with this novel implant system to document if it can simplify the surgical pr...

متن کامل

The combination of polytetrafluoroethylene mesh and titanium rib implants: an innovative process for reconstructing large full thickness chest wall defects.

OBJECTIVES The reconstruction of large full thickness chest wall defect after resection of T3/T4 non-small cell lung cancer (NSCLC) or primary chest wall tumours presents a technical challenge for thoracic surgeons and is a critical factor in determining post-operative outcome. When the defect is large, complications are common with a 27% mean rate of respiratory morbidity. METHODS Since 2006...

متن کامل

Treatment of Intercondylar Humeral Fractures With 3D-Printed Osteosynthesis Plates

The aim of the study was to evaluate the efficacy custom 3D-printed osteosynthesis plates in the treatment of intercondylar humeral fractures.Thirteen patients with distal intercondylar humeral fractures were randomized to undergo surgery using either conventional plates (n = 7) or 3D-printed plates (n = 6) at our institution from March to October 2014. Both groups were compared in terms of ope...

متن کامل

Crossed Kirschner’s wires for the treatment of anterior flail chest: an extracortical rib fixation

Objective: Thoracic trauma may be a life-threatening condition. Flail chest is a severe chest injury with high mortality rates. Surgery is not frequently performed and, in Literature, data are controversial. The authors report their experience in the treatment of flail chest by an extracortical internal-external stabilization technique with Kirshner’s wires (K-wires). <...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of trauma

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 2005