Intraarterial CT Angiography Using Ultra Low Volume of Iodine Contrast – Own Experiences
نویسندگان
چکیده
BACKGROUND High volume of intravenous contrast in CT-angiography may result in contrast-induced nephropathy. Intraarterial ultra-low volume of contrast medium results in its satisfactory blood concentration with potentially good image quality. The first main purpose was to assess the influence of the method on function of transplanted kidney in patients with impaired graft function. The second main purpose of the study was to evaluate the usefulness of this method for detection of gastrointestinal and head-and-neck haemorrhages. MATERIAL/METHODS Between 2010 and 2013 intraarterial CT-angiography was performed in 56 patients, including 28 with chronic kidney disease (CKD). There were three main subgroups: 18 patients after kidney transplantation, 10 patients with gastrointestinal hemorrhage, 8 patients with head-and-neck hemorrhage. Contralateral or ipsilateral inguinal arterial approach was performed. The 4-French vascular sheaths and 4F-catheters were introduced under fluoroscopy. Intraarterial CT was performed using 64-slice scanner. The scanning protocol was as follows: slice thickness 0.625 mm, pitch 1.3, gantry rotation 0.6 sec., scanning delay 1-2 sec. The extent of the study was established on the basis of scout image. In patients with CKD 6-8 mL of Iodixanol (320 mg/mL) diluted with saline to 18-24 mL was administered at a speed of 4-5 mL/s. RESULTS Vasculature was properly visualized in all patients. In patients with impaired renal function creatinine/eGFR levels remained stable in all but one case. Traditional arteriography failed and CT-angiography demonstrated the site of bleeding in 3 of 10 patients with symptoms of gastrointestinal bleeding (30%). In 8 patients with head-and-neck bleeding CT-angiography did not prove beneficial when compared to traditional arteriography. CONCLUSIONS 1. Ultra-low contrast intraarterial CT-angiography does not deteriorate the function of transplanted kidneys in patients with impaired graft function. 2. 3D reconstructions allow for excellent visualization of vascular anatomy of renal transplants. 3. Intraarterial CT-angiography is useful for detection of the bleeding site.
منابع مشابه
Assessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran
Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...
متن کاملUltra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic angiography.
OBJECTIVES This study sought to evaluate the feasibility of using ultra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic (CT) angiography to follow diagnostic cardiac catheterization. BACKGROUND Cardiovascular interventions such as percutaneous aortic valve replacement require transfemoral delivery of large-bore intra-arterial catheters; therefore, pre-procedura...
متن کاملHigh-Pitch, Low-Voltage and Low-Iodine-Concentration CT Angiography of Aorta: Assessment of Image Quality and Radiation Dose with Iterative Reconstruction
OBJECTIVE To assess the image quality of aorta obtained by dual-source computed tomography angiography (DSCTA), performed with high pitch, low tube voltage, and low iodine concentration contrast medium (CM) with images reconstructed using iterative reconstruction (IR). METHODS One hundred patients randomly allocated to receive one of two types of CM underwent DSCTA with the electrocardiogram-...
متن کاملNeuroradiologic applications of intraarterial digital subtraction angiography.
In the neuroradiologic evaluation of 118 patients using intraarterial digital subtraction angiography definite advantages and disadvantages were defined. Advantages include reduction of contrast medium volume, catheter time, and patient risk and discomfort. It also aids in angiographic planning. The paramount disadvantage is less spatial resolution compared with conventional film angiography.
متن کاملSubmillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging
OBJECTIVES To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. MATERIALS AND METHODS Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different prot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 80 شماره
صفحات -