[Indirect method of measuring the scatter X-ray fraction using collimators in the diagnostic domain].
نویسندگان
چکیده
The lead disc method is conventionally applied to measure the scatter fraction directly in the energy range of diagnostic X-rays. There are numerous reports of use of this method, but it is difficult to make lead discs with sufficient fabrication accuracy. In this paper, we newly propose an indirect measurement method using collimators instead. In our method, we measure the following two experimental values: the sum of the intensities of the direct X-rays and scattered X-rays, and the intensity of direct X-rays using lead collimators. The ratio of these two values shows the fraction of the direct X-ray that is the complementary value of the scatter fraction. To verify this method experimentally, we carried out experiments using a computed radiography system at tube voltages of 40 kV to 100 kV, and phantom thicknesses of 10 mm to 100 mm. The results confirmed the validity of our method.
منابع مشابه
Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5
Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...
متن کاملIntroducing an Optimized Method for Obtaining X-ray Diffraction Patterns of Biological Tissues
Introduction Individual X-Ray diffraction patterns of biological tissues are obtained via interference of coherent scattering with their electrons. Many scientists have distinguished normal and cancerous breast tissue, bone density, and urinary stone types using the X-Ray diffraction patterns resulting from coherent scattering. The goal of this study was to introduce an optimized method for obt...
متن کاملQuality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran
Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...
متن کاملPaediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran
Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...
متن کاملCalculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement
Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...