SNR and functional sensitivity of BOLD and perfusion-based fMRI using arterial spin labeling with spiral SENSE at 3 T.
نویسندگان
چکیده
Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) studies using parallel imaging to reduce the readout window have reported a loss in temporal signal-to-noise ratio (SNR) that is less than would be expected given a purely thermal noise model. In this study, the impact of parallel imaging on the noise components and functional sensitivity of both BOLD and perfusion-based fMRI data was investigated. Dual-echo arterial spin labeling data were acquired on five subjects using sensitivity encoding (SENSE), at reduction factors (R) of 1, 2 and 3. Direct recording of cardiac and respiratory activity during data acquisition enabled the retrospective removal of physiological noise. The temporal SNR of the perfusion time series closely followed the thermal noise prediction of a radicalR loss in SNR as the readout window was shortened, with temporal SNR values (relative to the R=1 data) of 0.72 and 0.56 for the R=2 and R=3 data, respectively, after accounting for physiological noise. However, the BOLD temporal SNR decreased more slowly than predicted even after accounting for physiological noise, with relative temporal SNR values of 0.80 and 0.63 for the R=2 and R=3 data, respectively. Spectral analysis revealed that the BOLD trends were dominated by low-frequency fluctuations, which were not dominant in the perfusion data due to signal processing differences. The functional sensitivity, assessed using mean F values over activated regions of interest (ROIs), followed the temporal SNR trends for the BOLD data. However, results for the perfusion data were more dependent on the threshold used for ROI selection, most likely due to the inherently low SNR of functional perfusion data.
منابع مشابه
Perfusion-based FMRI in the monkey brain at 7T: Investigations of CASL parameters
A. C. Zappe, H. Merkle, J. Pfeuffer, N. K. Logothetís Department: Physiology of Cognitive Processes, Max Planck Institute, Tuebingen, Germany, Laboratory of molecular imaging, NIH/NINDS, Bethesda, MD, United States, MREA Neuro, Siemens Medical Solutions, Erlangen, Germany Introduction Perfusion-based FMRI has become a powerful tool in recent years to achieve high spatial resolution [1]. Perfusi...
متن کاملBayesian Joint Detection-Estimation of Cerebral Vasoreactivity from ASL fMRI Data
Although the study of cerebral vasoreactivity using fMRI is mainly conducted through the BOLD fMRI modality, owing to its relatively high signal-to-noise ratio (SNR), ASL fMRI provides a more interpretable measure of cerebral vasoreactivity than BOLD fMRI. Still, ASL suffers from a low SNR and is hampered by a large amount of physiological noise. The current contribution aims at improving the r...
متن کاملArterial spin labeling perfusion fMRI with very low task frequency.
Functional magnetic resonance imaging (fMRI) has become the most widely used modality for visualizing regional brain activation in response to sensorimotor or cognitive tasks. While the majority of fMRI studies have used blood oxygenation level-dependent (BOLD) contrast as a marker for neural activation, baseline drift effects result in poor sensitivity for detecting slow variations in neural a...
متن کاملSupport vector machine classification of arterial volume‐weighted arterial spin tagging images
INTRODUCTION In recent years, machine-learning techniques have gained growing popularity in medical image analysis. Temporal brain-state classification is one of the major applications of machine-learning techniques in functional magnetic resonance imaging (fMRI) brain data. This article explores the use of support vector machine (SVM) classification technique with motor-visual activation parad...
متن کاملA signal processing model for arterial spin labeling functional MRI.
A model of the signal path in arterial spin labeling (ASL)-based functional magnetic resonance imaging (fMRI) is presented. Three subtraction-based methods for forming a perfusion estimate are considered and shown to be specific cases of a generalized estimate consisting of a modulator followed by a low pass filter. The performance of the methods is evaluated using the signal model. Contaminati...