BrachyGUI: an adjunct to an accelerated Monte Carlo photon transport code for patient-specific brachytherapy dose calculations and analysis
نویسندگان
چکیده
A number of accelerated Monte Carlo (MC) codes have been developed in recent years for brachytherapy applications, one of which is PTRAN_CT. Developed as an extension to the well-benchmarked PTRAN code, PTRAN_CT can be used to perform efficient patientspecific dose calculations. The code can explicitly account for the patient geometry converted from computed-tomography (CT) images, as well as perturbations due to the brachytherapy applicator and seeds. We have developed a software tool called BrachyGUI that provides an integrated environment for preparing patient and treatment plan-specific input data files for PTRAN_CT. It also comes with dose calculation, analysis, and treatment planning capabilities. In this article, we will describe the interface of BrachyGUI with PTRAN_CT for CT-based calculations, and examine the calculation efficiency of PTRAN_CT. We conclude that it is now feasible to use PTRAN_CT for high dose rate brachytherapy treatment planning on a routine clinical basis.
منابع مشابه
Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code
Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...
متن کاملAccuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...
متن کاملComparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
متن کاملDosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty
Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...
متن کاملRadial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations
Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three 60Co sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a go...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007