New assay of apolipoproteins A-I and B by rate nephelometry evaluated.

نویسندگان

  • J J Maciejko
  • S S Levinson
  • L Markyvech
  • M P Smith
  • R D Blevins
چکیده

We evaluated new, commercially available reagents for assaying apolipoproteins (apo) A-I and B by rate nephelometry (INA). Our initial linearity studies for apoA-I indicated that use of the commercial diluent resulted in incomplete immunoreactivity. Subsequent revision of the calibration line by the manufacturer compensated for this and improved the linearity for the apoA-I assay. We observed good linearity for the apoB assay. The within-run CVs were less than 4.0% and the between-run CVs were less than 5.5% for both assays. Results were 109% for apoA-I and 101% for apoB as compared with those measured for IUIS-WHO reference materials from the Centers for Disease Control. Recovery averaged 103% for apoA-I and 105% for apoB, for duplicate assays of three concentrations of purified apoA-I and low-density lipoprotein (LDL). Assaying sera from 45 patients, we demonstrated a good correlation between INA and radial immunodiffusion for both apoA-I (r = 0.92) and apoB (r = 0.95). Correlations between apoA-I and high-density lipoprotein cholesterol, and between apoB and LDL cholesterol compared favorably with previous reports. We conclude that these assays are accurate, precise, and easily automated for clinical application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunoturbidimetric method for routine determinations of apolipoproteins A-I and B.

A simple immunoturbidimetric method for quantifying apolipoproteins (apo) A-I and B in serum or plasma is described. A special reagent formulation, including large amounts of suitable detergents, obviates the need for a sample blank even with grossly lipemic specimens. The assay is rapid, easily automated, and thus convenient for routine work. For both apo A-I and apo B, the assay range is abou...

متن کامل

Determination of apolipoprotein B by kinetic (rate) nephelometry.

Determination of apoB by rate nephelometry is a simple, rapid and precise method, which is also suitable for a routine laboratory. It can be standardized with lipoprotein-B or LDL fractions, but only if these fractions are diluted with fresh whole serum. The standardization is also valid for VLDL if the samples are diluted with hydroxypolyethoxydodecane (trade name: Thesit) in a concentration o...

متن کامل

Nephelometry of apolipoprotein B in human serum.

We studied the development of light scattering in the reaction between anti-apolipoprotein B and apolipoprotein B in intact very-low-density lipoproteins (I) and low-density lipoproteins (II) as well as in lipoproteins treated with lipases, and found considerable differences in the kinetics of the immunoreaction for the two lipoprotein classes. Pre-incubation with triglyceride lipase and choles...

متن کامل

Quantitation of beta-lipoprotein in cord serum by rate nephelometric immunoassay: a potential screening test for familial hypercholesterolemia.

We measured beta-lipoprotein in 232 cord sera by rate nephelometry and compared the results with those obtained by electroimmunoassay. The mean (mean +/- two standard deviations) was 544 (293-1009) mg/L by rate nephelometry and 503 (265-955) mg/L by electroimmunoassay. The between-assay correlation coefficient was 0.891. Between-run coefficients of variation were 3.5-4.4% for nephelometry and 1...

متن کامل

Method-dependent variations in the stability of apolipoprotein B in a stabilized liquid reference material.

Using accelerated Arrhenius-type short-term and long-term temporal studies, we evaluated the storage life of a stabilized, liquid-frozen reference material (SLRM) for human apolipoprotein B (apo B) developed by the International Federation of Clinical Chemistry. As measured by our candidate reference RIA, the concentrations of immunoreactive apo B in the SLRM showed pronounced degradation with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 11  شماره 

صفحات  -

تاریخ انتشار 1987