Hemodynamic and Humoral Response to Intubation with Double-lumen Endotracheal Tubes Versus Single-lumen Tubes Combined with an Endobronchial Blocker: A Randomized Clinical Trial

نویسندگان

  • Sabine Nabecker
  • Georg Grubhofer
  • Helmut Hager
  • Georg Goliasch
  • Henrik Fischer
  • Martin Bernardi
  • Daniel I Sessler
چکیده

Introduction: Insertion of endotracheal tubes, especially large and relatively inflexible double-lumen tubes, provokes cardiovascular and humoral responses which can cause complications. Bronchial blockers, combined with conventional single-lumen tubes (SLT), serve as alternatives to double-lumen tubes (DLT) and may provoke less hemodynamic response. Methods: Forty adults scheduled for elective thoracic surgery requiring single-lung ventilation were randomly assigned to DLT or SLT combined with EZ-Blocker (EZ), a bronchial blocker. Heart rate and arterial blood pressure were recorded before induction of anesthesia, before laryngoscopy, after laryngoscopy, and one minute after intubation. Epinephrine, norepinephrine, and cortisol serum concentrations were assessed one minute after intubation. Results: Pre-laryngoscopy values were comparable in both groups. Mean arterial pressure significantly increased in both groups during intubation. The maximum value during intubation was significantly higher with DLT (121 ± 17 mmHg), compared to bronchial blocker (105 ± 18 mmHg, P=0.022). Heart rate increased significantly during intubation in both groups (DLT from 68 ± 9 to 86 ±11, P<0.001, bronchial blocker from 72 ±11 to 87 ± 16, P=0.002), but the increase did not differ between the groups (P=0.76). Epinephrine, norepinephrine, and cortisol serum concentrations did not increase significantly from baseline values and did not differ between the treatment groups. Conclusion: Insertion of DLT increases blood pressure more than placement of a SLT combined with bronchial blocker. However, the difference is probably not clinically important. Furthermore, there were no significant differences in heart rate or catecholamine concentrations. Clinicians should consider other factors when choosing between airway options for single-lung ventilation. Citation: Nabecker S, Grubhofer G, Hager H, Goliasch G, Fischer H, et al. (2014) Hemodynamic and Humoral Response to Intubation with Doublelumen Endotracheal Tubes Versus Single-lumen Tubes Combined with an Endobronchial Blocker: A Randomized Clinical Trial. J Anesth Clin Res 5: 377. doi:10.4172/2155-6148.1000377

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Airway injuries after one-lung ventilation: a comparison between double-lumen tube and endobronchial blocker: a randomized, prospective, controlled trial.

BACKGROUND Vocal cord injuries, postoperative hoarseness, and sore throat are common complications after general anesthesia. One-lung ventilation can be achieved via two techniques: double-lumen endotracheal tube or endobronchial blocker such as the Arndt blocker. The current study was designed to assess the impact of these techniques for one-lung ventilation on the incidence and severity of po...

متن کامل

Two lung ventilation through single lumen tracheal tube in thoracoscopic thymectomy: a randomized clinical trial of efficacy and safety.

BACKGROUND Video assisted thoracoscopic surgery (VATS) has been successfully used for thymectomy in myasthenia gravis (MG). Thoracoscopic thymectomy (TT) is usually done under general anesthesia with double lumen tubes (DLT). The aim of this study is evaluation of two lung ventilation through single lumen tubes (SLT) during TT. METHODS In this prospective randomized study, TT was done in 30 p...

متن کامل

Double-lumen endotracheal tube for one-lung ventilation through a fresh tracheostomy stoma: a case report.

For one-lung ventilation in many surgical cases, double-lumen endotracheal tubes are the first-line choice for airway management. For most cases, double-lumen endotracheal tubes are faster, easier to place, cheaper, and less prone to malposition than today's bronchial blocker devices. This report describes an elective tracheostomy and the use of a double-lumen endotracheal tube directly through...

متن کامل

The Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers.

BACKGROUND A novel double-lumen endotracheal tube, the Papworth BiVent tube, has been designed to allow the rapid passage of a blocker into either main bronchus, without fibreoptic endoscopic guidance. METHODS The feasibility of lung isolation and one-lung ventilation (OLV) in human cadavers is examined, along with displacement of the bronchus blocker during head and neck movement. RESULTS ...

متن کامل

A randomized, double-blind comparison of licorice versus sugar-water gargle for prevention of postoperative sore throat and postextubation coughing.

BACKGROUND One small study suggests that gargling with licorice before induction of anesthesia reduces the risk of postoperative sore throat. Double-lumen tubes are large and thus especially likely to provoke sore throats. We therefore tested the hypothesis that preoperative gargling with licorice solution prevents postoperative sore throat and postextubation coughing in patients intubated with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014