Responses of contralateral SI and SII in cat to same-site cutaneous flutter versus vibration.

نویسندگان

  • M Tommerdahl
  • B L Whitsel
  • O V Favorov
  • C B Metz
  • B L O'Quinn
چکیده

The methods of (14)C-2-deoxyglucose ((14)C-2DG) metabolic mapping and optical intrinsic signal (OIS) imaging were used to evaluate the response evoked in the contralateral primary somatosensory receiving areas (SI and SII) of anesthetized cats by either 25 Hz ("flutter") or 200 Hz ("vibration") sinusoidal vertical skin displacement stimulation of the central pad on the distal forepaw. Unilateral 25-Hz stimulation consistently evoked a localized region of elevated (14)C-2DG uptake in both SI and SII in the contralateral hemisphere. In contrast, 200-Hz stimulation did not evoke elevated (14)C-2DG uptake in the contralateral SI but evoked a prominent, localized region of increased (14)C-2DG uptake in the contralateral SII. Experiments in which the OIS was recorded yielded results that complemented and extended the findings obtained with the 2DG method. First, 25-Hz central-pad stimulation evoked an increase in absorbance in a region in the contralateral SI and SII that corresponded closely to the region in which a similar stimulus evoked increased (14)C-2DG uptake. Second, 200-Hz stimulation of the central pad consistently evoked a substantial increase in absorbance in the contralateral SII but very little or no increase in absorbance in the contralateral SI. And third, 200-Hz central-pad stimulation usually evoked a decrease in absorbance in the same contralateral SI region that underwent an increase in absorbance during same-site 25-Hz stimulation. Experiments in which the OIS responses of both SI and SII were recorded simultaneously demonstrated that continuous (>1 s) 25-Hz central-pad stimulation evokes a prominent increase in absorbance in both SI and SII in the contralateral hemisphere, whereas only SII undergoes a sustained prominent increase in absorbance in response to 200-Hz stimulation to the same central-pad site. SI exhibits an initial, transient increase in absorbance in response to 200-Hz stimulation and at durations of stimulation >1 s, undergoes a decrease in absorbance. It was found that the stimulus-evoked absorbance changes in the contralateral SI and SII are correlated significantly during vibrotactile stimulation of the central pad-positively with 25-Hz stimulation and negatively with 200-Hz stimulation. The findings are interpreted to indicate that 25-Hz central-pad stimulation of the central pad evokes spatially localized and vigorous neuronal activation within both SI and SII in the contralateral hemisphere and that although 200-Hz stimulation evokes vigorous and well maintained neuronal activation within the contralateral SII, the principal effect on the contralateral SI of a 200-Hz stimulus lasting >1 s is inhibitory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of high-frequency skin stimulation on SI cortex: mechanisms and functional implications.

Optical intrinsic signal (OIS) imaging methods were used to record the responses of contralateral SI cortex to 25 Hz ("flutter") and also to 200 Hz ("vibration") stimulation of the skin. Anesthetized cats and squirrel monkeys were subjects. Separate series of experiments were carried out to evaluate the contralateral SI response to continuous, multisecond 25 Hz vs. 200 Hz stimulation (a) at mul...

متن کامل

Parallel activation of primary and secondary somatosensory cortices in human pain processing.

Cerebral processing of pain has been shown to involve primary (SI) and secondary (SII) somatosensory cortices. However, the temporal activation pattern of these cortices in nociceptive processing has not been demonstrated so far. We therefore used whole-head magnetoencephalography to record cortical responses to cutaneous laser stimuli in six healthy human subjects. By using selective nocicepti...

متن کامل

\"DOMINANCY\" IN THE SECOND SOMATOSENSORY AREA REVEALED BY MAGNE TOENCEPHALOGRAPHY

The second somatosensory area (SlI) has been studied both by electrical evoked potentials24 and magnetoencephalography (MEG)5 Magnetic evoked fields of contralateral primary somatosensory and ipsilateral second somatosensory cortices of 12 normal subjects were recorded in response to median nerve electrical stimulation by means of a single magnetometer. We detected. in addition to the usua...

متن کامل

Functional overlap of finger representations in human SI and SII cortices.

We aimed to find out to what extent functional representations of different fingers of the two hands overlap at the human primary and secondary somatosensory cortices SI and SII. Somatosensory evoked fields (SEFs) were recorded with a 306-channel neuromagnetometer from 8 subjects. Tactile stimuli, produced by diaphragms driven by compressed air, were delivered to the fingertips in three differe...

متن کامل

Simultaneous early processing of sensory input in human primary (SI) and secondary (SII) somatosensory cortices.

Simultaneous early processing of sensory input in human primary (SI) and secondary (SII) somatosensory cortices. The anatomic connectivity of the somatosensory system supports the simultaneous participation of widely separated cortical areas in the early processing of sensory input. We recorded evoked neuromagnetic responses noninvasively from human primary (SI) and secondary (SII) somatosensor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 82 4  شماره 

صفحات  -

تاریخ انتشار 1999