Wavefront- versus topography-guided customized ablations with the NIDEK EC-5000 CX II in surface ablation treatment: refractive and aberrometric outcomes.

نویسندگان

  • Paolo Vinciguerra
  • Elena Albè
  • Fabrizio I Camesasca
  • Silvia Trazza
  • Daniel Epstein
چکیده

PURPOSE To compare the long-term refractive outcomes and changes in higher order wavefront aberrations in patients undergoing photorefractive keratectomy (PRK) with topography-guided (CATz) or wavefront-guided (OPDCAT) ablation algorithm using the NIDEK Advanced Vision Excimer Laser System (NAVEX). METHODS A retrospective 12-month follow-up study was conducted of 226 eyes undergoing PRK. The NIDEK EC-5000 CX II excimer laser and Final Fit 1.11 treatment planning software were used. Sixty-eight eyes underwent OPDCAT ablation and 158 eyes underwent CATz ablation. Mean preoperative manifest refractive spherical equivalent (MRSE) was -5.73 +/- 2.03 diopters (D) (range: -11.25 to -2.50 D) in the OPDCAT group and -3.77 +/- 3.78 D (range: -12.50 to -5.75 D) in the CATz group. RESULTS At 12 months postoperatively, mean MRSE was 0.05 D for the OPDCAT group and plano for the CATz group. Stability was similar in both groups as were visual outcomes. No eyes lost 2 or more lines of BSCVA at 6 months postoperatively or later. Mean ocular wavefront higher order aberrations at 3 months postoperatively were 0.44 +/- 0.17 microm for the OPDCAT group and 0.55 +/- 0.27 microm for the CATz group. CONCLUSIONS Refractive outcomes were equivalent between eyes that underwent PRK with wavefront-guided ablation and those that underwent topography-guided ablation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Slit skiascopic-guided ablation using the Nidek laser.

PURPOSE To present the approach of using a scanning slit refractometer (the ARK 10000) in conjunction with a corneal topography system to guide customized corneal ablation. This diagnostic system is coupled with the Nidek EC-5000 system which combines scanning slit and a scanning small area ablation (1.0 mm) to perform a customized ablation. METHODS The ARK 10000 diagnostic system which conta...

متن کامل

Smoothness of ablation on polymethylmethacrylate plates with four scanning excimer lasers.

PURPOSE To perform a quantitative evaluation of smoothness of ablation on polymethylmethacrylate (PMMA) using four scanning excimer lasers available commercially for photorefractive surgery. METHODS Ablations were done on PMMA plates with dimensions 100 x 50 x 1 mm. Four scanning excimer lasers were used, two with flying spot technology (Zeiss-Meditec MEL-70, and a Russian-made unit, Microsca...

متن کامل

Topography-guided laser refractive surgery.

PURPOSE OF REVIEW Topography-guided laser refractive surgery regularizes the front corneal surface irregularities to achieve the desired refractive outcome. This is particularly applicable in highly aberrated corneas, where wavefront aberrometry is often not possible. This article aims to review the recently published results of topography-guided ablations in normal regular corneas, highly aber...

متن کامل

Topography-guided (NIDEK customized aspheric treatment zone) photorefractive keratectomy with mitomycin C after penetrating keratoplasty for keratoconus: case report.

PURPOSE To report topography-guided photorefractive keratectomy (PRK) with mitomycin C (MMC) after penetrating keratoplasty for keratoconus. METHODS A 34-year-old woman with irregular astigmatism after penetrating keratoplasty in the right eye underwent PRK. Topography-guided surface ablation using the customized aspheric treatment zone ablation (CATz) was programmed for a 5.00-mm optical zon...

متن کامل

Outcomes of topography-guided versus wavefront-optimized laser in situ keratomileusis for myopia in virgin eyes.

PURPOSE To compare the outcomes of topography-guided and wavefront-optimized treatment in patients having laser in situ keratomileusis (LASIK) for myopia. SETTING Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India. DESIGN Prospective contralateral-eye case study. METHODS Patients had topography-guided LASIK in 1 eye and wavefront-optimized LA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 23 9 Suppl  شماره 

صفحات  -

تاریخ انتشار 2007