Interpolated Compressed Sensing for 2D Multiple Slice Fast MR Imaging
نویسندگان
چکیده
Sparse MRI has been introduced to reduce the acquisition time and raw data size by undersampling the k-space data. However, the image quality, particularly the contrast to noise ratio (CNR), decreases with the undersampling rate. In this work, we proposed an interpolated Compressed Sensing (iCS) method to further enhance the imaging speed or reduce data size without significant sacrifice of image quality and CNR for multi-slice two-dimensional sparse MR imaging in humans. This method utilizes the k-space data of the neighboring slice in the multi-slice acquisition. The missing k-space data of a highly undersampled slice are estimated by using the raw data of its neighboring slice multiplied by a weighting function generated from low resolution full k-space reference images. In-vivo MR imaging in human feet has been used to investigate the feasibility and the performance of the proposed iCS method. The results show that by using the proposed iCS reconstruction method, the average image error can be reduced and the average CNR can be improved, compared with the conventional sparse MRI reconstruction at the same undersampling rate.
منابع مشابه
Enhancement of the low resolution image quality using randomly sampled data for multi-slice MR imaging.
Low resolution images are often acquired in in vivo MR applications involving in large field-of-view (FOV) and high speed imaging, such as, whole-body MRI screening and functional MRI applications. In this work, we investigate a multi-slice imaging strategy for acquiring low resolution images by using compressed sensing (CS) MRI to enhance the image quality without increasing the acquisition ti...
متن کاملAccelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k
Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...
متن کاملCompressed Sensing with Transform Domain Dependencies for Coronary MRI
Fig 3: Comparison of BLS-GSM CS and l1 norm CS for imaging of right coronary artery. Fig. 1: a) Wavelet coefficients of a 2D slice of a coronary image. b) Random permutation of the same coefficients shown in (a). Both data have equivalent lp norm, which suggests CS lp norm regularizers do not take into account the clustering and correlation of information in the transform domain. Compressed Sen...
متن کاملEfficient 2D MRI relaxometry using compressed sensing.
Potential applications of 2D relaxation spectrum NMR and MRI to characterize complex water dynamics (e.g., compartmental exchange) in biology and other disciplines have increased in recent years. However, the large amount of data and long MR acquisition times required for conventional 2D MR relaxometry limits its applicability for in vivo preclinical and clinical MRI. We present a new MR pipeli...
متن کاملCompressed Sensing based Diffusion Spectrum Imaging
Introduction: Several methods are currently used to resolve multiple fibers within a voxel including Q-space imaging such as DSI and QBI. These approaches are generally limited by the burden of dense sampling in Q-space to avoid aliasing, which makes their application to clinical studies difficult. However, compressed sensing (CS) can attain almost perfect reconstruction from incomplete random ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -