Activity during Your Fellowship
نویسندگان
چکیده
Widely used medical imaging systems in clinics currently rely on x-rays, magnetic resonance imaging, ultrasound, computed tomography, and positron emission tomography. The aforementioned technologies provide clinical data with a variety of resolution, implementation cost, and use complexity, where some of them rely on ionizing radiation. Microwave sensing and imaging (MSI) is an alternative method based on non-ionizing electromagnetic (EM) signals operating over the frequency range covering hundreds of MHz to tens of GHz. The advantages of using EM signals are low health risk, low cost implementation, low operational cost, ease of use, and user friendliness. Advancements made in microelectronics, material science, and embedded systems make it possible for miniaturization and integration into portable, handheld, mobile devices with networking capability. MSI has been used for tumour detection, blood clot/stroke detection, heart imaging, bone imaging, cancer detection, and localization of in-body RF sources. The fundamental notion of MSI is that it exploits the tissue dependent dielectric contrast to reconstruct signals and images using radar-based or tomographic imaging techniques. This paper presents a comprehensive overview of the active MSI for various medical applications, for which the motivation, challenges, possible solutions, and future directions are discussed. 2. R. Chandra, and Ilangko Balasingham, “Investigations on the Effect of Frequency and Noise in a Localization Technique Based on Microwave Imaging for an In-body RF source,” in Proceeding of SPIE Defence, Security and Sensing, Baltimore, April 2015 [Accepted] Abstract: Localization of a wireless capsule endoscope finds many clinical applications from diagnostics to therapy. There are potentially two approaches of the electromagnetic waves Localization of a wireless capsule endoscope finds many clinical applications from diagnostics to therapy. There are potentially two approaches of the electromagnetic waves based localization: a) signal propagation model based localization using a priori information about the person’s dielectric channels, and b) recently developed microwave imaging based localization without using any a priori information about the person’s dielectric channels. In this paper, we study the second approach in terms of a variety of frequencies and signal-tonoise ratios for localization accuracy. To this end, we select a 2-D anatomically realistic numerical phantom for microwave imaging at different frequencies. The selected frequencies are 13.56 MHz, 431.5 MHz, 920 MHz, and 2380 MHz that are typically considered for medical applications. Microwave imaging of a phantom will provide us with an electromagnetic model with electrical properties (relative permittivity and conductivity) of the internal parts of the body and can be useful as a foundation for localization of an in-body RF source. Low frequency imaging at 13.56 MHz provides a low resolution image with high contrast in the dielectric properties. However, at high frequencies, the imaging algorithm is able to image only the outer boundaries of the tissues due to low penetration depth as higher frequency means higher attenuation. Furthermore, recently developed localization method based on microwave imaging is used for estimating the localization accuracy at different frequencies and signal-tonoise ratios. Statistical evaluation of the localization error is performed using the cumulative distribution function (CDF). Based on our results, we conclude that the localization accuracy is minimally affected by the frequency or the noise. However, the choice of the frequency will become critical if the purpose of the method is to image the internal parts of the body for tumour and/or cancer detection. 3. R. Chandra, and Ilangko Balasingham, “Detection of Brain Tumour and Localization of a Deep Brain RF-source Using Microwave Imaging,” in Proceeding of the 9th European Conference on Antennas and Propagation, EUCAP, Lisbon, April 2015 [Accepted] Abstract: This paper presents a feasibility study using numerical simulations for microwave This paper presents a feasibility study using numerical simulations for microwave imaging based brain tumour detection. An anatomically realistic numerical phantom with a model of brain tumour is used, where scattered electromagnetic signals are generated using the phantom by finite-difference-time-domain (FDTD) simulations. The microwave imaging technique based on Levernberg-Marquadt iterative scheme is used to solve the inverse scattering problem for the head of the phantom in the 403.5 MHz medical radio (MedRadio) band. Two-dimensional quantitative images having the electrical properties of the brain are reconstructed. Differential images are obtained by taking the difference between the reconstructed images with and without the tumour model, and with and without the expected effect of the contrast agents. Although it is difficult to detect a small tumour in the reconstructed image, a tumour of diameter 5 mm can be detected in the differential image in high signal-to-noise ratio (SNR) cases. The simulation results show that at least 45 dB SNR is required for small size tumour detection. Moreover, the paper presents a study of a localization method based on microwave imaging for deepbrain RF-source. The method can be useful for precise positioning of a neuroendoscope. The simulation results show that it is possible to localize a deep-brain RF-source in two dimensions with a localization accuracy of 5 mm at an SNR of 30 dB. 4. R. Chandra, and Anders J Johansson, “Analytical Model, Measurements, and Effect of Outer Lossless Shell of Phantoms for On-body Propagation Channel Around the Body for Body Area Networks,” in Proceeding of the 9th European Conference on Antennas and Propagation, EUCAP, Lisbon, April 2015 [Accepted] Abstract: This paper presents the experimental verification of an analytical model for the propagation channel for the devices placed around body in body area networks. Measurements are done over a semi-solid physical phantom using on-body antennas. A good agreement between the analytical model and the measurements is obtained at 2.4 GHz. Further, the effect of the outer lossless shell, usually present in the phantoms, is discussed. This paper presents the experimental verification of an analytical model for the propagation channel for the devices placed around body in body area networks. Measurements are done over a semi-solid physical phantom using on-body antennas. A good agreement between the analytical model and the measurements is obtained at 2.4 GHz. Further, the effect of the outer lossless shell, usually present in the phantoms, is discussed. Through simulations, it is shown that the outer lossless shell results in decreasing the link loss for around the body propagation whereas the effect of the shell for along the body propagation
منابع مشابه
The Interview Process for Gastroenterology Fellowship
Gastroenterology has become one of the most competitive fellowship in the field of internal medicine. 1 The application phase usually starts during the second half of PGY-2 year, and includes writing a personal statement, completing an application form via the electronic residency application service (ERAS), obtaining letters of recommendations, and selecting the programs to apply for. The inte...
متن کاملChoosing a Post-Fellowship Path
While the gastroenterology career path is by no means short, for many of us it was relatively straightforward. If, like me, you knew you wanted to pursue gastroenterology, you moved from medical school to residency to fellowship relatively seamlessly, without need for significant pause or reflection. Yet during fellowship, there is a looming fork in the road. Mentors ask about your career goals...
متن کاملGardner, York and Block
Dear Mr. York: As reader services correspondent at Fellowship headquarters, I would like to thank you for sending us your review article of Martin Gardner's Urantia. Of the half-dozen reviews we've read, yours is certainly the most serious, insightful and heartening. It was also gratifying to learn that you met your first Urantia Book believers during your visit to our information center at the...
متن کاملThe University of Kansas School of Medicine.
Thank you for considering the University of Kansas Medical Center for your residency/fellowship training. Choosing a residency program is one of the most important decisions of your medical career. In order to facilitate your application process at KUMC we recommend you review the following link http://www.kumc.edu/school-of-medicine/gme/prospective-residentsfellows.html which is located on the...
متن کاملERS clinical fellowship report
An ERS clinical fellowship is an excellent opportunity to discover and develop a new field in your medical career http://ow.ly/WmiY306uzUM.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015