One-Step Transepithelial Topography-Guided Ablation in the Treatment of Myopic Astigmatism

نویسندگان

  • Aleksandar Stojanovic
  • Shihao Chen
  • Xiangjun Chen
  • Filip Stojanovic
  • Jia Zhang
  • Ting Zhang
  • Tor Paaske Utheim
چکیده

PURPOSE To evaluate one-step topography-guided transepithelial ablation in the treatment of low to moderate myopic astigmatism using a 1KHz excimer laser. METHODS Retrospective study of 117 consecutive eyes available for evaluation 12 months after surgery. Pre- and post-operative visual and refractive data as well as post-operative pain and haze were analyzed. A novel technique integrating custom refractive- and epithelial- ablation in a single uninterrupted procedure was used. RESULTS The mean pre-operative spherical equivalent (SE) and the mean cylinder were: -3.22 diopters (D) ±1.54 (SD) (range -0.63 to -7.25 D) and -0.77 D ±0.65 (range 0 to -4.50 D), respectively. At 12 months after surgery: no eyes lost ≥2 lines of corrected distant visual acuity (CDVA). Safety and efficacy indexes were 1.27 and 1.09, respectively. Uncorrected distant visual acuity (UDVA) was ≥20/20 in 96.6% of the eyes. Manifest refraction spherical equivalent was within ±0.5 D of the desired refraction in 93.2% of the eyes. Average root mean square (RMS) wavefront error measured at central 6 mm, increased from 0.38 pre-operatively to 0.47 µm post-operatively. Refractive stability was achieved and sustained 1 month after surgery. No visually significant haze was registered during the observation period. Post-operative pain was reported in 4.5% of patients. CONCLUSIONS One-step transepithelial topography-guided treatment for low to moderate myopia and astigmatism performed with a 1 KHz laser, provided safe, effective, predictable and stable results with low pain and no visually significant haze.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transepithelial, Topography-guided Ablation in the Treatment of Visual Disturbances in LASIK Flap or Interface Complications.

PURPOSE To evaluate the efficacy and safety of a single-step, transepithelial, topography-guided surface ablation in the treatment of visual disturbances including irregular astigmatism and light scattering caused by LASIK flap or interface complications. METHODS Seventeen eyes of 16 patients with LASIK flap or interface complications and central residual stromal thickness ≥300 μm were treate...

متن کامل

Two-step LASIK with topography-guided ablation to correct astigmatism after penetrating keratoplasty.

PURPOSE To assess the efficacy, predictability, stability, and safety of a two-step LASIK procedure using topography-guided ablation to correct astigmatism after penetrating keratoplasty. METHODS Fifteen eyes of 15 patients underwent a two-step LASIK procedure at the Maggiore Hospital of Bologna, Italy. In the first step, a flap was created using the Hansatome microkeratome. In the second ste...

متن کامل

Clinical Outcomes of SMILE With a Triple Centration Technique and Corneal Wavefront-Guided Transepithelial PRK in High Astigmatism.

PURPOSE To comparatively investigate the clinical outcomes, vector parameters, and corneal aberrations of small incision lenticule extraction (SMILE) with a triple centration technique and corneal wavefront-guided transepithelial photorefractive keratectomy (PRK) for the correction of high astigmatism. METHODS This retrospective, comparative case series study included 89 eyes (89 patients) th...

متن کامل

Polar Value Analysis of Low to Moderate Astigmatism with Wavefront-Guided Sub-Bowman Keratomileusis

PURPOSE To evaluate the astigmatic outcomes of wavefront-guided sub-Bowman keratomileusis (WFG-SBK) for low to moderate myopic astigmatism. METHODS This study enrolled 100 right eyes from 100 patients who underwent WFG-SBK for the correction of myopia and astigmatism. The polar value method was performed with anterior and posterior corneal astigmatism measured with Scheimpflug camera combined...

متن کامل

Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK

PURPOSE To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. SETTING Private clinical ophthalmology practice. PATIENTS AND METHODS A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013