Mattauch-Herzog Type Mass Spectrograph with a Two Stage Electrostatic Field

ثبت نشده
چکیده

It is very complicated to calculate the secondorder aberrations of complex analyser systems and mistakes are liable to be made. Even if the matrix method is used the tediousness of the calculation is not altered. The usefulness of the matrix representation comes from the fact that the over-all transfer matrix of the total system is easily written as a product of the transfer matrices of various parts of the system. Hence the calculation of the second-order aberration is reduced to the mere mechanical calculation of matrix products. For the case of the numerical calculation by digital computer, the matrix method may be advantageous to programming.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compatibility of Spatially Coded Apertures with a Miniature Mattauch-Herzog Mass Spectrograph.

In order to minimize losses in signal intensity often present in mass spectrometry miniaturization efforts, we recently applied the principles of spatially coded apertures to magnetic sector mass spectrometry, thereby achieving increases in signal intensity of greater than 10× with no loss in mass resolution Chen et al. (J. Am. Soc. Mass Spectrom. 26, 1633-1640, 2015), Russell et al. (J. Am. So...

متن کامل

Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source.

A Mattauch-Herzog geometry mass spectrograph (MHMS) has been equipped with a novel array detector, the focal plane camera (FPC). The FPC consists of an array of gold Faraday cups, each coupled to its own integrator, with interrogation of the integrators performed by a multiplexer. The initial coupling of this instrument with a pin-type glow discharge source has provided limits of detection in t...

متن کامل

The effect of wall strengtheners on the performance of double-stage electrostatic precipitators

The presence of wall strengtheners in double-stage electrostatic precipitators affects gas velocity, electrical field and particle movement over the ESP. In this work we have used our previous mathematical model for double-stage ESP {Talaie et. al (2001) [10]] to study the effect of wall strengtheners on the performance of double-stage ESP. One of the important findings was that, due to the fac...

متن کامل

Novel Wet Electrostatic Precipitator for Sub - Micron Particles

The waste incineration plants, power generation utility, chemical industry, etc. require the efficient removal of submicrometer particles from raw gases. Wet electrostatic precipitators (WESP) are the most effective control device for fine aerosol from the humid raw gases. They use less energy than mechanical collection devices, have no moving parts to wear, their maintenance costs are lower, p...

متن کامل

An introduction to ion optics for the mass spectrograph.

A mass spectrograph is an instrument that separates and simultaneously focuses ions, along a focal plane, of different mass/charge ratios that are diverging in direction and that have a variable velocity. With these instruments and a spatially sensitive ion detector, simultaneous detection can be employed, which has been shown to improve precision and throughput (as compared to a mass spectrome...