Extrapolation-Based References Improve Motion and Eddy-Current Correction of High B-Value DWI Data: Application in Parkinson’s Disease Dementia
نویسندگان
چکیده
PURPOSE Conventional motion and eddy-current correction, where each diffusion-weighted volume is registered to a non diffusion-weighted reference, suffers from poor accuracy for high b-value data. An alternative approach is to extrapolate reference volumes from low b-value data. We aim to compare the performance of conventional and extrapolation-based correction of diffusional kurtosis imaging (DKI) data, and to demonstrate the impact of the correction approach on group comparison studies. METHODS DKI was performed in patients with Parkinson's disease dementia (PDD), and healthy age-matched controls, using b-values of up to 2750 s/mm2. The accuracy of conventional and extrapolation-based correction methods was investigated. Parameters from DTI and DKI were compared between patients and controls in the cingulum and the anterior thalamic projection tract. RESULTS Conventional correction resulted in systematic registration errors for high b-value data. The extrapolation-based methods did not exhibit such errors, yielding more accurate tractography and up to 50% lower standard deviation in DKI metrics. Statistically significant differences were found between patients and controls when using the extrapolation-based motion correction that were not detected when using the conventional method. CONCLUSION We recommend that conventional motion and eddy-current correction should be abandoned for high b-value data in favour of more accurate methods using extrapolation-based references.
منابع مشابه
Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.
Diffusion-weighted imaging (DWI) obtained with interleaved echo-planar imaging (EPI) pulse sequence has great potential of characterizing brain tissue properties at high spatial-resolution. However, interleaved EPI based DWI data may be corrupted by various types of aliasing artifacts. First, inconsistencies in k-space data obtained with opposite readout gradient polarities result in Nyquist ar...
متن کاملComprehensive approach for correction of motion and distortion in diffusion-weighted MRI.
Patient motion and image distortion induced by eddy currents cause artifacts in maps of diffusion parameters computed from diffusion-weighted (DW) images. A novel and comprehensive approach to correct for spatial misalignment of DW imaging (DWI) volumes acquired with different strengths and orientations of the diffusion sensitizing gradients is presented. This approach uses a mutual information...
متن کاملDiscarded image volumes and gradient table alignment: how much do they affect DTI tensor calculations?
Introduction: Several preprocessing steps are applied to raw DTI image sets prior to the calculation of tensor model parameters. Before the preprocessing steps, it is a common practice to discard some of the diffusion weighted image (DWI) volumes (or slices) if there are artifacts. After the bad volumes are discarded, the second step is to apply spatial transformations to align all DWI and non-...
متن کاملCognitive profile and determinants of poor cognition in people without dementia in Parkinson’s disease
Background: The Montreal Cognitive Assessment (MoCA) has been recommended as a cognitive screening tool for clinical practice and research in Parkinson’s disease (PD), yet no normative data have been published for MoCA in PD without dementia. Methods: We undertook a pooled secondary analysis of data from two studies (one cross-sectional design and one clinical trial) conducted in the East ...
متن کاملHigh b-value diffusion imaging of dementia: application to vascular dementia and alzheimer disease.
Alzheimer's disease (AD) and Vascular Dementia (VaD) are the most common types of dementia and are progressive diseases affecting millions of people. Despite the high sensitivity of MRI to neurological disorders it has not thus far been found to be specific for the detection of either of these pathologies. In the present study high b-value q-space diffusion-weighted MRI (DWI) was applied to VaD...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2015