Comparison of Conventional versus Steerable-Catheter Guided Coronary Sinus Lead Positioning in Patients Undergoing Cardiac Resynchronization Device Implantation.

نویسندگان

  • Fikret Er
  • Dilek Yüksel
  • Martin Hellmich
  • Natig Gassanov
چکیده

OBJECTIVES The aim of this study was to compare conventional versus steerable catheter guided coronary sinus (CS) cannulation in patients with advanced heart failure undergoing cardiac resynchronization therapy (CRT). BACKGROUND Steerable catheter guided coronary sinus cannulation could reduce fluoroscopy time and contrast medium use during CRT implantation. METHODS 176 consecutive patients with ischemic and non-ischemic heart failure undergoing CRT implantation from January 2008 to December 2012 at the University Hospital of Cologne were identified. During the study period two concurrent CS cannulation techniques were used: standard CS cannulation technique (standard-group, n = 113) and CS cannulation using a steerable electrophysiology (EP) catheter (EPCath-group, n = 63). Propensity-score matched pairs of conventional and EP-catheter guided CS cannulation made up the study population (n = 59 pairs). Primary endpoints were total fluoroscopy time and contrast medium amount used during procedure. RESULTS The total fluoroscopy time was 30.9 min (interquartile range (IQR), 19.9-44.0 min) in the standard-group and 23.4 min (IQR, 14.2-34-2 min) in the EPCath-group (p = 0.011). More contrast medium was used in the standard-group (60.0 ml, IQR, 30.0-100 ml) compared to 25.0 ml (IQR, 20.0-50.0 ml) in the EPCath-group (P<0.001). CONCLUSIONS Use of steerable EP catheter was associated with significant reduction of fluoroscopy time and contrast medium use in patients undergoing CRT implantation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Double-wire technique for implanting a left ventricular venous lead in patients with complicated coronary venous anatomy].

INTRODUCTION AND OBJECTIVES Occasionally, implanting a left ventricular pacing electrode for cardiac resynchronization therapy via the coronary sinus may be complicated by the presence of anatomical structures that obstruct the access to the target vein. Our objective was to report on experience using a double-wire technique for implanting left ventricular venous leads gained at the Dr Negrín H...

متن کامل

Three-dimensional coronary sinus reconstruction-guided left ventricular lead implantation based on intraprocedural rotational angiography: a novel imaging modality in cardiac resynchronization device implantation.

AIMS Rotational angiography (RA) of the coronary sinus (CS) provides more anatomical insights compared with static angiographies. We evaluated intraprocedural three-dimensional (3D) CS reconstruction (RC) based on RA, using syngo(®) DynaCT Cardiac to guide CS lead implantation. METHODS AND RESULTS In 24 patients with indication for cardiac resynchronization therapy, intraprocedural RA and 3D ...

متن کامل

Cardiac Resynchronization Therapy: Lead Positioning and Technical Advances

Cardiac resynchronization therapy (CRT) is a therapeutic option for heart failure patients with a severely reduced left ventricular ejection fraction and left bundle branch block (Cleland et al., 2001). Ventricular resynchronization is achieved by biventricular pacing, usually via electrodes in the right ventricular apex and a left ventricular (LV) electrode positioned in a coronary vein. About...

متن کامل

Cardiac Resynchronization Therapy

In this issue of the Journal, Giraldi et al. (1) compare transvenous and epicardial lead placement in patients with unfavorable coronary sinus anatomy. Patients who met standard criteria for cardiac resynchronization therapy (CRT) including left ventricular (LV) dysfunction, New York Heart Association class III to IV congestive heart failure, and left bundle branch block, who were on optimal me...

متن کامل

Planning and Guidance of Cardiac Resynchronization Therapy–Lead Implantation by Evaluating Coronary Venous Anatomy Assessed with Multidetector Computed Tomography

OBJECTIVES We sought to evaluate the utility of multidetector computed tomography (MDCT) in preoperative planning of cardiac resynchronization therapy (CRT) device implantation. BACKGROUND Variation in coronary venous anatomy can affect optimal lead placement and may warrant preimplantation visualization prior to CRT lead placement. METHODS Prospective randomized enrollment of 29 patients (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • PloS one

دوره 10 11  شماره 

صفحات  -

تاریخ انتشار 2015