High-Resolution Light-Field Microscopy

نویسندگان

  • Chien-Hung Lu
  • Stefan Muenzel
  • Jason W. Fleischer
چکیده

By combining a high-resolution image from a standard camera with a low-resolution wavefront measurement from a Shack-Hartmann sensor, we numerically reconstruct a highresolution light field. We experimentally demonstrate the method with a commercially available microscope. ©2013 Optical Society of America OCIS codes: (110.0180) Microscopy; (110.1758) Computational imaging; (100.6640) Superresolution; The light field of an optical signal simultaneously stores spatial (x) and spatial frequency (k) information in a fourdimensional description. It accounts for the locally varying coherence of an optical beam and treats propagation in the full {x,k} phase space, allowing such features as numerical image refocusing [1]. A popular method to capture light field is using a lenslet array, which is able to obtain the four-dimensional information in a single shot. The lenslet configuration has been used in a variety of contexts, ranging from aberration correction in adaptive optics [2] to plenoptic photography [3] and microscopy [4]. However, the use of an array limits both spatial and angular sampling, resulting in poor resolution in both domains. Recently, a full resolution of the light-field measurement by using a spatial light modulator (SLM) has been proposed [5]. In this method, the SLM creates a scanning aperture for extracting spatial frequency from a spatially localized window position. However, the use of an SLM increases the complexity of the imaging system, while the requirement of point-by-point scanning decreases the acquisition speed. To date, there has been no method available for high-speed, high-resolution light-field imaging. Here, we develop a computational method to overcome these practical issues. By combining two shots, one from a coarse-grained lenslet array and one from a charge-coupled device (CCD) camera, a high resolution light field can be reconstructed. The method involves an iterative process with a realspace image, IR, taken by a conventional CCD camera, and a light field image, ILF, taken by a ShackHartmann wave-front sensor. A schematic of the algorithm is shown in Fig. 1. In the first step, the algorithm expands ILF by a factor of eight in spatial domain using linear interpolation, and then executes the fast Fourier transform (FFT). In the Fourier space, we put the constraint of IR as a projection (by Fourier slice theorem) and then apply an inverse fast Fourier transform (IFFT) back. In the computed light field, we put constraints on the consistency of measured ILF , viz. that the light field is real and nonnegative, and then apply a FFT again. We repeat the cycle of FFT, IFFT and constraints iteratively until convergence happens. The final output is a high-resolution light field, ILF. Figure 1. Schematics of propsed algorithm. A proof-of-principle experiment, shown in Fig. 2. A white light source is concentrated by a 10X/0.25 objective lens and illuminates a tiled air force resolution chart. Transmitted light is then collected by a 4f imaging system, with a a 20X/0.4 objective as a front lens and a back lens with focal length 15cm.While a beamsplitter could be used to collect both IR and ILF simultaneously, we measure them sequentially here. We first record a real-space image using a conventional CCD camera with pixel size of 4.65 μm (Thorlabs DCU224) and then switch to a Shack-Hartmann wavefront sensor (Thorlabs WFS150-5C) for a (low resolution) light-field image. After these two measurements, we perform the iteration algorithm to reconstruct a high-resolution light field. Once the high-resolution light field is known, we are able to generate super-resolved images at different focal plans by a simple shearing transformation [2-4]. Fig. 3 shows the computed sequence of focusing of the tiled resolution chart from element 6 to element 3 of group 5 with improved resolution. Fig. 3(a-c) are obtained by using a lenslet array in a single shot, we can observe that the use of the lenslet array results in poor resolution and limited the depth of view. Fig. 3(d) is the measured image using the CCD camera (i.e. IR). By combining IR and ILF in the proposed algorithm, the high-resolution light field is reconstructed using 5 iterations. A series of focused images can then be generated computationally by the reconstructed light field. Fig. 3(e) and (f) show a significant improvement on both resolution and depth of view, with the bars and numbers of the chart more clearly visible. Figure 2. Schematic of the proof-of-principle experiment Figure 3. Computed sequence of focusing of the tiled resolution chart with improved resolution: different axial depths of view by (a-c) conventional lenslet array measurement. (d-f) by using our reconstructed high-resolution light-field (d) at starting focal plan with the element 6 (e) moving focal plan 100μm to the element 5 (d) moving focal plan 200μm to the element 4 and 3. We now extend the method to a commercial microscope by integrating the Shack-Hartmann wavefront sensor and the CCD camera with a digital refelcted light microscope (Olympus BX60M). Fig. 4 shows the computed axial slices of the tissue paper using a 20X/0.4 objective by a single lenslet measurement and the proposed method. As before, the new method gives more details in both lateral and axial directions, including the width of a variety of fibers from 5μm to 50μm, the micro-holes among fibers, and the relative depth of these micro-structures (shown by white arrows). Figure 4. Computed axial slices of the tissue paper using 20X/0.4 objective: different axial depths by (a-d) conventional lenslet array measurement. (e-h) by reconstructed light field (e) at starting focal plan, (f) moving focal plan 33μm, (g) moving focal plan 49μm, (h) moving focal plan 66μm. In conclusion, we have demonstrated a high-resolution light-field imaging method by combining measurements from a coarse-grained Shack-Hartmann sensor and a high-resolution image from a conventional digital camera. With the proposed iterative algorithm, a super-resolved sequence of focusing, axial slices and refocusing can be reconstructed computationally. The images show a significant improvement in both lateral and axial resolution. The integration with an existing commercial microscope further proves useful of the proposed method. This paves a way for high-resolution three-dimensional microscopy without optical sectioning or manual scanning.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional resolution doubling in wide-field fluorescence microscopy by structured illumination.

Structured illumination microscopy is a method that can increase the spatial resolution of wide-field fluorescence microscopy beyond its classical limit by using spatially structured illumination light. Here we describe how this method can be applied in three dimensions to double the axial as well as the lateral resolution, with true optical sectioning. A grating is used to generate three mutua...

متن کامل

SPED Light Sheet Microscopy: Fast Mapping of Biological System Structure and Function

The goal of understanding living nervous systems has driven interest in high-speed and large field-of-view volumetric imaging at cellular resolution. Light sheet microscopy approaches have emerged for cellular-resolution functional brain imaging in small organisms such as larval zebrafish, but remain fundamentally limited in speed. Here, we have developed SPED light sheet microscopy, which comb...

متن کامل

High numerical aperture tabletop soft x-ray diffraction microscopy with 70-nm resolution.

Light microscopy has greatly advanced our understanding of nature. The achievable resolution, however, is limited by optical wavelengths to approximately 200 nm. By using imaging and labeling technologies, resolutions beyond the diffraction limit can be achieved for specialized specimens with techniques such as near-field scanning optical microscopy, stimulated emission depletion microscopy, an...

متن کامل

Particle tracking and inference in fluorescence microscopy

Observing biophysical phenomena at the nanometer scale with both high spatial and temporal resolution is a challenging feat. Although many techniques, including atomic force microscopy and scanning electron microscopy, have demonstrated subnanometer spatial resolution, most exhibit drawbacks which limit their temporal resolution. On the other hand, light microscopy exhibits poor spatial resolut...

متن کامل

An overview of scanning near-field optical microscopy in characterization of nano-materials

Scanning Near-Field Optical Microscopy (SNOM) is a member of scanning probe microscopes (SPMs) family which enables nanostructure investigation of the surfaces on a wide range of materials. In fact, SNOM combines the SPM technology to the optical microscopy and in this way provide a powerful tool to study nano-structures with very high spatial resolution. In this paper, a qualified overview of ...

متن کامل

Wave optics theory and 3-D deconvolution for the light field microscope.

Light field microscopy is a new technique for high-speed volumetric imaging of weakly scattering or fluorescent specimens. It employs an array of microlenses to trade off spatial resolution against angular resolution, thereby allowing a 4-D light field to be captured using a single photographic exposure without the need for scanning. The recorded light field can then be used to computationally ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013