Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments

نویسندگان

  • Marcus Ang
  • Wesley Chong
  • Huiqi Huang
  • Wan Ting Tay
  • Tien Yin Wong
  • Ming-Guang He
  • Tin Aung
  • Jodhbir S. Mehta
چکیده

OBJECTIVE To compare anterior segment parameters measured using a semi-automatic software (Zhongshan Angle Assessment Program, ZAP) applied to anterior segment optical coherence tomography (AS-OCT) images, with commonly used instruments. METHODS Cross-sectional study of a total of 1069 subjects (1069 eyes) from three population-based studies of adults aged 40-80 years. All subjects underwent AS-OCT imaging and ZAP software was applied to determine anterior chamber depth (ACD), central corneal thickness (CCT), anterior and keratometry (K) - readings. These were compared to auto-refraction, keratometry and ocular biometry measured using an IOLMaster, ultrasound pachymeter and auto-refractor respectively. Agreements between AS-OCT (ZAP) and clinical instrument modalities were described using Bland-Altman, 95% limits of agreement (LOA). RESULTS The mean age of our subjects was 56.9±9.5 years and 50.9% were male. The mean AS-OCT (ZAP) parameters of our study cohort were: ACD 3.29±0.35 mm, CCT 560.75±35.07 µm; K-reading 46.79±2.72 D. There was good agreement between the measurements from ZAP analysis and each instrument and no violations in the assumptions of the LOA; albeit with a systematic bias for each comparison: AS-OCT consistently measured a deeper ACD compared to IOLMaster (95% LOA -0.24, 0.55); and a thicker CCT for the AS-OCT compared to ultrasound pachymetry (16.8±0.53 µm 95% LOA -17.3, 50.8). AS-OCT had good agreement with auto-refractor with at least 95% of the measurements within the prediction interval (P value <0.001). CONCLUSION This study demonstrates that there is good agreement between the measurements from the AS-OCT (ZAP) and conventional tools. However, small systematic biases remain that suggest that these measurement tools may not be interchanged.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography.

AIM To assess lens thickness measurements with anterior segment-optical coherence tomography (AS-OCT) in comparison with A-scan ultrasonography (A-scan US). METHODS There were 218 adult subjects (218 eyes) aged 59.2±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity...

متن کامل

Central Corneal Thickness in Spectral-Domain OCT and Associations with Ocular and Systemic Parameters

Background. Optical coherence tomography (OCT) allows quantitative analysis of the anterior segment of the eye with a noncontact examination. The aim of this study is to analyze associations of central corneal thickness (CCT) as measured by OCT with ocular and systemic cardiovascular parameters. Methods. A cross-sectional study of 734 persons was performed in a working age population. Only heal...

متن کامل

Comparison of central corneal thickness measured with anterior segment optical coherence tomography versus ultrasonic pachymetry.

PURPOSE To compare central corneal thickness measured with anterior segment optical coherence tomography (AS-OCT) and ultrasonic pachymetry (UP). METHOD A prospective, observational and cross-sectional study was performed. The central corneal thickness was measured in 112 eyes of 112 consecutive patients with AS-OCT and UP. All examinations were performed by the same examiner. The measurement...

متن کامل

Anterior Segment Time Domain Optical Coherence Tomography

To compare anterior segment parameters using quantitative imaging by anterior segment time domain optical coherence tomography (AS-OCT) and high frequency ultrasound biomicroscopy (HF-UBM). SETTING: Department of Ophthalmology at Bari University. METHODS: Seventy-two eyes of 72 subjects had anterior segment evaluation by AS-OCT (Stratus ver 6Zeiss) and HF-UBM (OTI-Scan HF35-50). Central corneal...

متن کامل

Fast segmentation of anterior segment optical coherence tomography images using graph cut

BACKGROUND Optical coherence tomography (OCT) is a non-invasive imaging system that can be used to obtain images of the anterior segment. Automatic segmentation of these images will enable them to be used to construct patient specific biomechanical models of the human eye. These models could be used to help with treatment planning and diagnosis of patients. METHODS A novel graph cut technique...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013