Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo

نویسندگان

  • Solenn Toupin
  • Pierre Bour
  • Matthieu Lepetit-Coiffé
  • Valéry Ozenne
  • Baudouin Denis de Senneville
  • Rainer Schneider
  • Alexis Vaussy
  • Arnaud Chaumeil
  • Hubert Cochet
  • Frédéric Sacher
  • Pierre Jaïs
  • Bruno Quesson
چکیده

BACKGROUND Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent. METHODS MR temperature mapping based on the Proton Resonance Frequency Shift (PRFS) method was performed at 1.5 T on the heart, with 4 to 5 slices acquired per heartbeat. Respiratory motion was compensated using navigator-based slice tracking. Residual in-plane motion and related magnetic susceptibility artifacts were corrected online. The standard deviation of temperature was measured on healthy volunteers (N = 5) in both ventricles. On animals, the MR-compatible catheter was positioned and visualized in the left ventricle (LV) using a bSSFP pulse sequence with active catheter tracking. Twelve MR-guided RFA were performed on three sheep in vivo at various locations in left ventricle (LV). The dimensions of the thermal lesions measured on thermal dose images, on 3D T1-weighted (T1-w) images acquired immediately after the ablation and at gross pathology were correlated. RESULTS MR thermometry uncertainty was 1.5 °C on average over more than 96% of the pixels covering the left and right ventricles, on each volunteer. On animals, catheter repositioning in the LV with active slice tracking was successfully performed and each ablation could be monitored in real-time by MR thermometry and thermal dosimetry. Thermal lesion dimensions on TD maps were found to be highly correlated with those observed on post-ablation T1-w images (R = 0.87) that also correlated (R = 0.89) with measurements at gross pathology. CONCLUSIONS Quantitative TD mapping from real-time rapid CMR thermometry during catheter-based RFA is feasible. It provides a direct assessment of the lesion extent in the myocardium with precision in the range of one millimeter. Real-time MR thermometry and thermal dosimetry may improve safety and efficacy of the RFA procedure by offering a reliable indicator of therapy outcome during the procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation

Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...

متن کامل

High spatial resolution thermal mapping of radiofrequency ablation lesions using a novel thermochromic liquid crystal myocardial phantom.

BACKGROUND Radiofrequency (RF) ablation causes thermal mediated irreversible myocardial necrosis. This study aimed to (i) characterize the thermal characteristics of RF ablation lesions with high spatial resolution using a thermochromic liquid crystal (TLC) myocardial phantom; and (ii) compare the thermochromic lesions with in vivo and in vitro ablation lesions. METHODS AND RESULTS The myocar...

متن کامل

64-element intraluminal ultrasound cylindrical phased array for transesophageal thermal ablation under fast MR temperature mapping: an ex vivo study.

This work was undertaken to investigate the feasibility of using a cylindrical phased array for transoesophaeal thermal ablation under magnetic resonance (MR) imaging guidance. Sixty-four transducers (0.45 mm wide by 15 mm tall), operating at 4.6 MHz, were spread around the periphery of a 10.6-mm-diam cylinder. The head of the applicator was covered with a 65-microm thick latex balloon attached...

متن کامل

New horizons in MR-controlled and monitored radiofrequency ablation of liver tumours

There is a sustained interest in using magnetic resonance (MR) thermometry to monitor the radiofrequency ablation of liver tumours as a means of visualizing the progress of the thermal coagulation and deciding the optimal end-point. Despite numerous technical challenges, important progress has been made and demonstrated in animal studies. In addition to MR thermometry, MR can now be used for th...

متن کامل

I-46: Radiofrequency Ablation of Uterine Fibroids

Uterine fibroids are benign solid tumors that are present in the majority of women. While often asymptomatic, fibroids can result in abnormal uterine bleeding, pelvic pressure, pain, subfertility, dyspareunia and other symptoms. Submucous and intramural fibroids are most associated with heavy menstrual bleeding; subserosal fibroids are more often innocuous unless sufficiently large so as to con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2017