Mean transit time for the assessment of myocardial perfusion by videodensitometry.

نویسندگان

  • N H Pijls
  • G J Uijen
  • A Hoevelaken
  • T Arts
  • W R Aengevaeren
  • H S Bos
  • J H Fast
  • K L van Leeuwen
  • T van der Werf
چکیده

The intrinsic limitations of coronary arteriography to predict the physiological effects of coronary obstructions are well known. Therefore, more direct assessments of the functional significance of coronary stenoses are becoming increasingly important. Study of contrast passage by electrocardiogram-triggered digital radiography has been proposed as a way of assessing changes in myocardial perfusion. The main problems in this approach are the limited time for motionless image acquisition, the potential alteration of vascular volume between different states, and the changing flow pattern induced by contrast agents. This has led to empiric substitution of mean transit time (Tmn) by other time parameters and to representation of vascular volume by maximal contrast intensity (Dmax). To avoid these problems, intact dogs were studied during almost motionless image acquisition of 20-25 consecutive paced heart beats obtained with synchronous radiographic pulses. In this way, unequivocal and reproducible determination of Tmn was possible. Constant and maximal vascular volume was created by continuous infusion of dipyridamole, and it was proved that coronary flow in this model was not influenced by contrast injections. Flow in the circumflex artery was measured by a ring mounted and calibrated Doppler probe. In each dog, flow in the circumflex artery was varied by a balloon occluder in 12 small steps (range, 0-174 +/- 42 ml/min). Inverse appearance time (1/Tapp), Dmax, Dmax/Tapp, inverse time of maximal intensity (1/Tmax), and 1/Tmn were calculated and the relations of these parameters to measured flow were investigated. Tmn proved to be the most reliable parameter for this purpose (r = 0.97 +/- 0.02; mean +/- SD), followed by Tmax (r = 0.93 +/- 0.04). Dmax failed to represent vascular volume but, in fact, showed a moderate correlation with flow (r = 0.78 +/- 0.22), as did Tapp (r = 0.64 +/- 0.18, 0.75 +/- 0.27, and 0.59 +/- 0.26 for the three definitions of Tapp used in this study). Dmax/Tapp correlated better with flow than either component separately. Our results indicate that the mean transit time calculated by videodensitometry can be used to accurately assess changes in myocardial perfusion strictly according to the original principles of indicator dilution theory.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

متن کامل

Comparison of the myocardial perfusion and wall motion results by ECG-Gated 99mTc-MIBI SPECT, before and after CABG for evaluation of myocardial viability [Persian]

It is of value to determine the amount of viable myocardial tissue in patients suffering from chronic coronary artery disease and ventricular dysfunction. Having the capability of evaluating both myocardial perfusion and function, simultaneously, myocardial scanning by ECG-Gated is an appropriate method for this purpose. The aim of this study was to compare the results of myocardial perfu...

متن کامل

Effects of depression on myocardial perfusion scintigraphy [Persian]

  Introduction: The relationship between depression and coronary artery disease is well established; however assessment of this relationship using functional and semi-quantitative imaging (myocardial perfusion scintigraphy) was lacking. The aim of this study was to assess the relationship between the severity of depression and the severity of myocardial perfusion abno...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 81 4  شماره 

صفحات  -

تاریخ انتشار 1990